background image

753737-100 Rev. B

7

DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE 

OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z124.1 AND A112.19.7.

ROUGHING-IN REFERENCES

SAVONA (MODEL 2901L)

CORNER (MODEL 6060L / V)

7"

(178mm)

76-3/4"

(1949mm)

54-1/2"

(1384mm)

65-3/8"

(1661mm)

 3"

(76mm)

  

7" (178mm)

15"

(381mm)

5-5/8" 

(143mm)

17-3/4"

(451mm)

10"

(254mm)

13-3/4" (349mm)

CUT OUT 

IN FLOOR FOR DRAIN

72”

(1829mm)

44”

(1118mm)

3”

(76mm)

12”

(305mm)

  8”

(203mm)

RECOMMENDED FITTING LOCATION 

64 X 279mm (2-1/2 X 11)

 

6”

(152mm)

  11-1/2”

(292mm)

5-1/2" 

(140mm)

CADET CORNER (MODEL 2775L)

15

24

m

m

(6

0)

70mm REF.
(2-3/4)

165mm

(6-1/2)

279mm

(11)

229 X 305mm
(9 X 12)
CUTOUT IN
FLOOR FOR
DRAIN

OUTLINE OF
CUTOUT

2159mm

(85)

1080 mm

(42-1/2)

C/L

1524mm

(60)

1076mm

(42-3/8)

1080mm

(42-1/2)

PUMP

C/L OF DRAIN OUTLET

5X42 (MODEL 2805L)

1524mm

(60)

INTEGRAL
FITTING DECK

762mm

(30)

1067mm

(42)

PROVIDE ACCESS
TO PUMP FOR
SERVICE ON ALL
INSTALLATIONS 

C/L OF
DRAIN

19mm
(3/4)

PUMP

305mm

(12)

152mm
(6)

RENAISSANCE (MODEL 2732)

60"

(1524mm)

33"

(838mm)

5-7/8" 

(149mm)

 

12"

(305mm)

6" 

(152mm)

3" 

(76mm)

8-1/2"

(216mm)

16-1/2"

(419mm)

CUT OUT IN FLOOR

FOR DRAIN

 1-1/2"

(38mm)

PROVIDE ACCESS TO 

PUMP FOR 

SERVICING ON ALL 

INSTALLATIONS

RECOMMENDED 

FITTING 

LOCATION 

64 X 330mm 

(2-1/2 X 13)

OUTLINE OF CUTOUT 

1486mm x 1029mm 

(58-1/2 x 40-1/2)

178mm x 381mm 
(7 x 15) 
FLOOR 
CUTOUT

Summary of Contents for 2425L / V -LHO

Page 1: ...ODEL 2422L LA V VA 5 x 32 MODEL 6060L V CORNER MODEL 2771L LA V VA 5 x 36 MODEL 2645L LA V VA OVAL MODEL 7236L LA V VA 6 x 36 MODEL 2425L V LHO 5 x 32 IA LHO MODEL 2425L V RHO 5 x 32 IA RHO MODEL 2732...

Page 2: ...nal Components Page Specifications Page 5 Roughing in Reference Page Framing and Support Instructions Page Mounting Instructions Page 10 Electrical Connections Page 11 0 0L V Corner EZ Install Heater...

Page 3: ...ribed in this manual Do not use any attachments not recommended by American Standard The unit must be connected only to a supply circuit that is properly protected by a ground fault circuit interrupte...

Page 4: ...of 1 x Stringers Drop Cloth Cement Plaster Grout General Installation Information Carefully uncrate and inspect your new bath for any shipping damage If such damage is found report it to your vendor i...

Page 5: ...mm 1 1 L 15 mm 0 W 1 mm 3 H 5 mm 1 1 L 1 mm 7 W 1 mm 3 H 5 mm 1 1 L 15 mm 0 W 13mm 3 H 5 1mm 0 1 L 1 7 mm W 1 mm 3 H 50 mm 1 3 L 15 mm 0 W 3 mm 3 3 H 50 mm 1 3 L 1 mm 7 W 111 mm H 55 mm L 1 7 mm W 1...

Page 6: ...LHO MODEL 2425L V LHO shown 5 x 32 IA RHO MODEL 2425L V RHO 0 15 mm 3 1 mm 3 7 mm 7 1 1 1mm 15 mm 11 7 mm 13 3 3 mm CUT OUT IN FLOOR FOR DRAIN 5 x 36 MODEL 2771L LA V VA 7 1 mm 3 1 mm 7 3 1 7mm 11 7 m...

Page 7: ...75L 1524m m 60 70mm REF 2 3 4 165mm 6 1 2 279mm 11 229 X 305mm 9 X 12 CUTOUT IN FLOOR FOR DRAIN OUTLINE OF CUTOUT 2159mm 85 1080 mm 42 1 2 C L 1524mm 60 1076mm 42 3 8 1080mm 42 1 2 PUMP C L OF DRAIN O...

Page 8: ...ELLISSE MODEL 2711L 1 mm 7 7mm 3 1 OUTLINE OF CUTOUT 17 1 X 11 1 70 1 X 1 C L OF DRAIN 10 mm PUMP 305mm 1 1 1 mm mm x 35 mm x 1 FLOOR CUTOUT RECOMMENDED FITTING LOCATION X 7 mm 1 X 11 OPTIONAL DECK F...

Page 9: ...irlpool following the drain installation instructions Before replacing your whirlpool for final installation be certain that an opening has been provided in the sub floor for the drain See the roughin...

Page 10: ...il Do not drill or cut the bath deck with the tub directly beneath it as damage to the tub may result 5 Remove the bath deck and apply a generous bead of waterproof sealant on the outer edge of the tr...

Page 11: ...lectrical codes Motor Hi Performance Rating 2 1 H P 1 4 H P and 1 25 H P 50 100 115V Power Line 150 200 12 10 8 8 The whirlpool should be installed on a 120 vac 15 amp dedicated GFCI circuit The circu...

Page 12: ...e heater will help maintain the temperature of the water in the bath Pressure Switch The heater is equipped with a preset pressure switch The pump must be running with water flowing in the whirlpool t...

Page 13: ...se and hang to dry Allowing bath mat to dry in the tub may cause surface damage Clean after use with a mild liquid household detergent cleaner Do not use Lestoil Lysol Disinfectant spray or concentrat...

Page 14: ...onsumer purchaser that it will at its option repair or replace this whirlpool or any of its parts that are found by American Standard in its sole judgment to be defective under normal residential use...

Page 15: ...ble for any other incidental or consequential damages attributable to a product defect or to the repair or exchange of a defective product all of which are expressly excluded from this warranty Some s...

Reviews: