The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as needed. Ensure 
roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the pump 
and controls. It is strongly recommended that an additional opening be provided for access to the drain components. The apron should not be used 
as the primary access opening.

TYPICAL PIER TYPE INSTALLATION

AS DESIRED

F

CUTOUT

AS DESIRED

G

CUTOUT

C

(10 mm)

1

(305 mm)

MOUNTING 

SURFACE

WATERPROOF
 SEALANT

BATH

TYPICAL RECESS INSTALLATION

(10 mm)

1

(305 mm)

C

E

D

W

LEVELING
STRINGERS

TILE

TILE

BEAD

STRIP

LEVELING STRINGER 

1 x  (not for support)

BATH

ADHESIVE

SEALANT

WALLBOARD

NOTE: Tile bead kit not included and  

            must be purchased separately.

C

TYPICAL INSTALLATION

FIGURE 1

     

This bath must be supported along its entire bottom.  Use mortar as bedding 

material (do not use sand or foam).  Apply enough mortar to support the complete 
bottom of the bath. After the mortar has been poured, and before it sets, position 
whirlpool or bath within recess until the rim is leveled against the leveling stringers (see 
"Typical Recess Installation") shown below.

            

    
    

The rim of the bath 

must not support weight.  Allow the mortar material to completely 

harden before applying weight to the rim or bottom of the bath. Any finish material such 
as tile or wall board must be self-supporting if it contacts the deck of the bath.

     

Replace whirlpool and re-shim the integral support feet, shimming the entire length of 

the support feet.  Secure the shims using construction adhesive, silicone, mortar or 
equivalent materials.  While not a necessity, the use of a foundation base consisting of 
cement, mortar, or grout will help provide a solid and secure installation.

3.

 Install drain components to the whirlpool following the drain installation instructions.  Before 

replacing your whirlpool for final installation, be certain that an opening has been provided in 
the sub-floor for the drain.  See the roughing-in drawing and Table 1 for suggested opening 
size (shadowed) and location dimensions. The drain/overflow of the bath extends below the 
bottom of the bath. Note that this requires a cutout in the floor.

 

     
    

The floor structure beneath the bath must be able to support a total weight of bath, water, and 

bather. Refer to Table 1 under total weight for your model.

For Models: 2425L/V-LHO, 2425L/V-RHO and 2732L/V;

For Models: 2645L/V, 2771L/V, 6060L/V, 7236L/V, 2422L/V and 2422LA/VA;

.

 Remove the whirlpool and attach a 1 x  stringer to the studs, with the top of the stringer touching the traced line. 

    The rim of the bath 

must not support weight.

1.

 Position the whirlpool into the installation opening and level the deck in both directions, shimming the integral support feet IF necessary. 

Mark the final position of the underside of the deck by tracing a line on to the studs (see Figure 1).

!

!

!

!

ACCESS PANEL MUST BE LOCATED 
ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON PUMP/MOTOR 
END FOR SERVICE.

ACCESS PANEL MUST BE LOCATED 
ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON 
PUMP/MOTOR END FOR SERVICE.

FOR E & D DIMENSIONS SEE 

TABLE 1 ON PAGE 5.

FOR G & F DIMENSIONS SEE 

TABLE 1 ON PAGE 5.

NOTE: 
FRONT EDGE 
OF BATH MUST 
BE SUPPORTED 
BY STUD WALL OR 
AMERICAN STANDARD 
APRON KIT

    

The rim of the bath 

must not support weight. If foundation base is used, allow the 

bedding material to completely harden before applying weight to the rim or bottom of 
the bath.  Any finish material such as tile or wall board must be self-supporting if it 
contacts the deck of the bath.

UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm) 

IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.

UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm) 

IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.

(EXCEPT 2425 WHERE APRON IS PRIMARY ACCESS OPENING)

ACCESS PANELS NOT REQUIRED 

FOR BATH TUBS.

ACCESS PANELS NOT REQUIRED 

FOR BATH TUBS.

Summary of Contents for 2425L / V -LHO

Page 1: ...ODEL 2422L LA V VA 5 x 32 MODEL 6060L V CORNER MODEL 2771L LA V VA 5 x 36 MODEL 2645L LA V VA OVAL MODEL 7236L LA V VA 6 x 36 MODEL 2425L V LHO 5 x 32 IA LHO MODEL 2425L V RHO 5 x 32 IA RHO MODEL 2732...

Page 2: ...nal Components Page Specifications Page 5 Roughing in Reference Page Framing and Support Instructions Page Mounting Instructions Page 10 Electrical Connections Page 11 0 0L V Corner EZ Install Heater...

Page 3: ...ribed in this manual Do not use any attachments not recommended by American Standard The unit must be connected only to a supply circuit that is properly protected by a ground fault circuit interrupte...

Page 4: ...of 1 x Stringers Drop Cloth Cement Plaster Grout General Installation Information Carefully uncrate and inspect your new bath for any shipping damage If such damage is found report it to your vendor i...

Page 5: ...mm 1 1 L 15 mm 0 W 1 mm 3 H 5 mm 1 1 L 1 mm 7 W 1 mm 3 H 5 mm 1 1 L 15 mm 0 W 13mm 3 H 5 1mm 0 1 L 1 7 mm W 1 mm 3 H 50 mm 1 3 L 15 mm 0 W 3 mm 3 3 H 50 mm 1 3 L 1 mm 7 W 111 mm H 55 mm L 1 7 mm W 1...

Page 6: ...LHO MODEL 2425L V LHO shown 5 x 32 IA RHO MODEL 2425L V RHO 0 15 mm 3 1 mm 3 7 mm 7 1 1 1mm 15 mm 11 7 mm 13 3 3 mm CUT OUT IN FLOOR FOR DRAIN 5 x 36 MODEL 2771L LA V VA 7 1 mm 3 1 mm 7 3 1 7mm 11 7 m...

Page 7: ...75L 1524m m 60 70mm REF 2 3 4 165mm 6 1 2 279mm 11 229 X 305mm 9 X 12 CUTOUT IN FLOOR FOR DRAIN OUTLINE OF CUTOUT 2159mm 85 1080 mm 42 1 2 C L 1524mm 60 1076mm 42 3 8 1080mm 42 1 2 PUMP C L OF DRAIN O...

Page 8: ...ELLISSE MODEL 2711L 1 mm 7 7mm 3 1 OUTLINE OF CUTOUT 17 1 X 11 1 70 1 X 1 C L OF DRAIN 10 mm PUMP 305mm 1 1 1 mm mm x 35 mm x 1 FLOOR CUTOUT RECOMMENDED FITTING LOCATION X 7 mm 1 X 11 OPTIONAL DECK F...

Page 9: ...irlpool following the drain installation instructions Before replacing your whirlpool for final installation be certain that an opening has been provided in the sub floor for the drain See the roughin...

Page 10: ...il Do not drill or cut the bath deck with the tub directly beneath it as damage to the tub may result 5 Remove the bath deck and apply a generous bead of waterproof sealant on the outer edge of the tr...

Page 11: ...lectrical codes Motor Hi Performance Rating 2 1 H P 1 4 H P and 1 25 H P 50 100 115V Power Line 150 200 12 10 8 8 The whirlpool should be installed on a 120 vac 15 amp dedicated GFCI circuit The circu...

Page 12: ...e heater will help maintain the temperature of the water in the bath Pressure Switch The heater is equipped with a preset pressure switch The pump must be running with water flowing in the whirlpool t...

Page 13: ...se and hang to dry Allowing bath mat to dry in the tub may cause surface damage Clean after use with a mild liquid household detergent cleaner Do not use Lestoil Lysol Disinfectant spray or concentrat...

Page 14: ...onsumer purchaser that it will at its option repair or replace this whirlpool or any of its parts that are found by American Standard in its sole judgment to be defective under normal residential use...

Page 15: ...ble for any other incidental or consequential damages attributable to a product defect or to the repair or exchange of a defective product all of which are expressly excluded from this warranty Some s...

Reviews: