background image

INSTALLATION INSTRUCTIONS

752535-100 Rev. F

© American Standard Inc. 2005
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.

HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS

REMINISCENCE
DROP-IN™ 

WHIRLPOOL

2908.XXXW SERIES

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

T H A N K     Y O U . . .

for selecting an American Standard bath. Your new 
bath is shipped to you after careful inspection. The 
whirlpool version is completely assembled with pump, 
motor, and system piping. All you need to finish the 
installation are your selected fittings and electrical 
connections for a whirlpool.

To insure maximum performance and pleasure from 
this product, please follow the instructions and 
cautions. 

GENERAL INSTALLATION INFORMATION

Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor 
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before 
enclosing with wallboard, tile, etc., water test the unit and check for leaks.

Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect 
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, 
motor, or piping system.

Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and 
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead 
(required for recess installations).

Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.  

WARNING! Do not lift whirlpool by the piping harness at any time.

List of Optional Components (not included):

•  Safe-T-Heater 9075.120*
* see your American Standard Distributor

List of Required Components (not included):

•  Drain 1583.470*          •  Bath Filler* 
* see your American Standard Distributor

List of Required Tools and Supplies:

Tools

•  Level
•  Tape Measure
•  Pipe Wrench
•  Slip Joint Pliers
•  Screw Driver
•  Standard
      Woodworking Tools
•  Personal Safety
      Equipment
•  Caulking Gun

Supplies

•  Nails
•  Putty
•  Caulking (waterproof)
•  1 x 3 or 2 x 2
      Stringers
•  Drop Cloth
•  15 or 20 amp
      GFI Outlet
•  Cement, Plaster,
      Grout

229 x 305mm
(9 X 12)
FLOOR
CUTOUT

1-1/2 N.P.T.M. THREADS

ROUGH

FLOOR

1-1/2 O.D.TAILPIECE

70mm

(2-3/4)

117mm
(4-5/8)

LEVELING STRINGER

(NOT FOR SUPPORT)

RIM AT
DRAIN END

C/L OF OVERFLOW

616mm

(24-1/4)

73mm

(2-7/8)

464mm

(18-1/4)

79mm

(3-1/8)

149mm REF.

(5-7/8)

64mm REF.
(2-1/2)

1676mm

(66)

PUMP

PROVIDE ACCESS

TO PUMP FOR SERVICE
ON ALL INSTALLATIONS

914mm

(36)

457mm

(18)

330mm

(13)

INTEGRAL

FITTING DECK

152mm

(6)

C/L OF
DRAIN
OUTLET

OUTLINE OF 

CUTOUT

ON/OFF

SWITCH

INTEGRAL

SUPPORT

FEET

SAFE-T-HEATER
REMOVABLE BLANK

  66 x 36 x 24-1/4 In. (1676 x 914 x 616mm)

95 Lbs. (43 Kg.)

659 Lbs. (299 Kg.)

68 Gal. (257 L.)
55 Gal. (208 L.)

40 x 18 In. (1016 x 457mm)
53 x 28 In. (1330 x 718mm)

15 In. (381mm)

40 Lbs./Sq. Ft. (191 Kgs/Sq. m.)

23.8
44.5

GENERAL SPECIFICATIONS FOR 2908 WHIRLPOOL

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT

3

)

WHIRLPOOL ELECTRICAL SPECIFICATIONS

1.6 HP, 9.7 AMPS, 120V.

2.1 HP, 15.6 AMPS, 120V.

SYSTEM I PUMP
SYSTEM II PUMP

Summary of Contents for Reminiscence Drop-In Whirlpool 2908.XXXW

Page 1: ...ll tiling bead required for recess installations Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth WARNING Do not lift whirlpool by the piping harness at any time List of Optional Components not included Safe T Heater 9075 120 see your American Standard Distributor List of Required Components not included Drain 1583 470 Bath Filler see your Amer...

Page 2: ...rlpool into the installation opening and level the deck shimming the integral support feet as necessary 2 Install drain components to the whirlpool following the manufacturers instructions Before replacing your whirlpool for installation be certain that an opening has been provided in the sub floor for the drain See the roughing in drawing for suggested opening size and location dimensions 3 Repla...

Page 3: ...ensed electrician and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be routed away from the pump body and heater if equipped 3 1 6 HORSEPOWER MODELS The whirlpool should be installed on a 120 vac 15 amp dedicated circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 3 wire circuit from the electric...

Page 4: ...LIC BATHTUB Your new acrylic bathtub has been molded in the newest plumbing fixture material available today Acrylics are tough durable finishes that are simple and easy to care for The colors have been formulated to match other American Standard fixtures and enhance your choice of bathroom decorations The high gloss surface is resistant to impact and chemicals and will retain its lasting luster w...

Reviews: