INStALLAtION - GAS UtILItY cONNEctIONS-StANDARDS AND cODES

Qualified installation personnel, licensed and bonded, must be experienced in such work, familiar with all precautions required and 

have complied with all requirements of state or local authorities having jurisdiction.

The ventilation of these fryers should be in accordance with local codes.  In absence of local codes, refer to the national ventilation 

code titled, Standard for the Installation of Equipment for the Removal of Smoke and Grease Laden Vapors from Commercial 

Cooking Equipment, NFPA-96-Latest Edition.

The appliance is to be installed with a check valve in accordance with applicable federal, province and local codes.

Owner’s Manual

         Countertop Fryer

13592 Desmond St., Pacoima, CA 91331   818.897.0808 tel  888.753.9898 toll free   www.americanrange.com

4

The installation instructions contained here are for the use of qualified 
installation and service personnel only.  Installation or service by other 
than certified / licensed personnel will void the warranty and will result 
in damage to the fryer and/or injury to the operator.

WARNING

!

The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, 

ANSI Z223.1NFPA54, or the Natural and Propane Gas Installation Code, CSA B149.1, as applicable, including:

1.   The appliance and its individual shut-off valve must be disconnected from the gas supply piping 

  system during any pressure testing of that system at test pressure in excess of 1/2 PSI (3.5KPa). 

2.   The appliance must be isolated from the gas supply piping system by closing its individually manual shut-off valve during 

  any pressure testing of the gas supply piping system at test pressure equal to or less then 1/2 PSI (3.5KPa).

The gas supply line must be at least 3/4” ID (inside dimensions) size as the gas inlet of the appliance.

INStRUctIONS

The area around the appliance must be keep free and clear of combustibles such as solvents, cleaning liquid, broom, rags, etc.

All threaded joints of the appliance piping must be sealed with a compound that is resistant to the action of natural gas or liquefied 

petroleum gases and the joint connection checked for gas leaks using a soapy water solution before lighting the pilots.

Proper clearances must be provided at the front of the appliance for servicing and proper operation.

For proper combustion and ventilation provisions shall be incorporated in the design of the kitchen, to ensure adequate supply of 

fresh air and adequate clearance for air openings into the combustion chamber.

For proper operation of the appliance, do not obstruct the flow of combustion and ventilation air.

A manual gas shut-off valve shall be installed when the appliance is connected to the gas supply.

The rating plate is located inside of the left side panel.

The connecting wiring diagram is located on the lower inside of the left side panel.

INStALLAtION

When installing the pressure regulator - remember it can only handle 1/2 PSI.  In 
every LPG installation, you have high source pressures, ranging from 20 PSI to 100 
PSI.  If the high pressure gas line from the LPG tank is directly connected to the unit 
without the proper step-down regulator, it will rupture the diaphragm in the valve, 
rendering it useless.

WARNING

!

GENERAL EXPORt INStALLAtIONS

 - 

Installation must conform to Local and National Standards.  Local installation codes 

and/or requirements may vary.  If you have any questions regarding the proper installation or operation of your American Range 

Fryer, please contact your local distributor.  If you do not have a local distributor, contact American Range Corporation at 

1.888.753.9898 or visit us at www.americanrange.com

Summary of Contents for AFCT-15

Page 1: ...OP FRYER MODEL NUMBERS AFct 15 PROFESSIONAL QUALITY COOKING EQUIPMENT 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com DESIGN CLASS FUNCTION 2012 America...

Page 2: ...______________________ Serial Number ___________________________________________ Purchase Date ___________________________________________ Installed By __________________________ Install Date ________...

Page 3: ...you should encounter any sort of problem turn to the section of the manual entitled Troubleshooting for a quick solution or guidance regarding the next step required to get back to tip top condition T...

Page 4: ...Manual 2 Shipping Damage Claim Procedure 3 Rating Plate 3 Clearances 3 INSTALLATION 4 7 Gas Utility Connections Standards Codes 4 Instructions 4 Fryers with Casters 4 Wiring Diagram 5 Models and Part...

Page 5: ...tructions for local inspectors and for future use WHATTO DO IFYOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call...

Page 6: ...d how to communicate your observations with authorized field service technicians Before using your appliance please read this manual paying special attention to the important safety instructions locat...

Page 7: ...15 999999 CO9999 GAS TYPE NAT TANK ID 2 MAN PRESS IN W C 4 0 INPUT BTU HOUR BURNER CLEARANCES NON COMB COMB 30 000 BACK SIDES 0 0 6 6 SUITABLE FOR INSTALLATION ON COMBUSTIBLE FLOORS USING 6 ADJ LEGS O...

Page 8: ...I 3 5KPa The gas supply line must be at least 3 4 ID inside dimensions size as the gas inlet of the appliance INSTRUCTIONS The area around the appliance must be keep free and clear of combustibles suc...

Page 9: ...CK WHITE RED WHITE COM NC NO HI LIMIT SWITCH NO C THERMOSTAT CAPILARY BULB CAPILARY BULB 4 0 0 3 5 0 3 0 0 2 5 0 2 0 0 OFF P I L O T ON OFF WHITE TP TH TH BLACK WIRING DIAGRAM Owner s Manual Counterto...

Page 10: ...rtop Fryer 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 6 COUNTERTOP FRYER DESCRIPTION AFCT 15 Basket Hanger 1 Baskets 2 Rack Screen 1 Burners 1 Drai...

Page 11: ...ent and accessible 0 Gas Supply line properly sized 0 Gas Supply pressure checked 0 Operating pressure checked 0 All connections checked for leaks INSTALLATION CHECKLIST This checklist has been develo...

Page 12: ...and the temperature that you cook at will determine how long the fryer oil can be used most can last up to 100 hours Depending on the menu and local eating patterns fryers will usually be operated at...

Page 13: ...vice before moving the appliance for cleaning and servicing 3 Drain the fryer into a filtered pan or steel container Flush out sediment at the bottom of fryer with liquid oil 4 Close the drain valve a...

Page 14: ...Manual Countertop Fryer 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 10 27 26 25 7 21 8 9 10 11 12 13 19 18 17 22 24 23 28 20 16 15 14 5 2 4 3 1 6 A...

Page 15: ...llivolt AF 16 71658 Bracket Thermostat AFCT 16GA Aluminized 17 71661 Top Hinge Assembly 18 A32013 KNOB RX Thermostat AF Series 19 A24000 Elbow Orifice Mixr 3 8C 3 8 27 20 A11114 Pilot 3CH 6 016 Nat Ga...

Page 16: ...ugh Unit preheats to 350 F in about ten minutes Thermostat may be defective Unit will require service Too little gas pressure dirty gas line Call for authorized service SYMPTOM General frying problems...

Page 17: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 18: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 19: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 20: ...certified licensed contractor Failure to comply will void any written or implied warranty Should the equipment require service during the standard warranty period the receipt proving certified instal...

Reviews: