Figure 3: Mounting Diagram
Connect Electrical
Note: Only licensed professionals should open the cover panel of unit.
1.
Determine the power capacity setting for the application (2.4 kW or 3.4
kW).
Model AHQ-B03X Electric Tankless Heater
Application
One sink with low
flow rate faucets
One sink with low
flow rate faucets
Power setting
selection
Setting 1
Setting 2
Power setting
3.4 kW
2.4 kW
Rated voltage
120 V 60 Hz
Current load
7 – 28.5 A
7 – 20 A
Breaker
required
30 A
20A
Wire size
required
10 AWG
12 AWG
2.
The unit requires a power cord be installed. The power cord selected will
be rated to handle up to 300 Volts and be of the wire size specified in the
chart above. To install the power cord, please follow these steps:
a)
Open the front panel of the unit by removing six small screws from the
back of the cover and then lift the front cover out.
b)
Unscrew and remove the cable clamp.
c)
Feed the 10 or 12 AWG electrical cable (not provided) into unit through
Summary of Contents for AHQ-B03X
Page 5: ...5 TYPICAL INSTALLATION Figure 1 Typical Installation Figure 2 Dimensions and Clearance ...
Page 13: ...13 ...
Page 22: ...5 INSTALACIÓN TÍPICA Figura 1 Instalación típica Figura 2 Dimensiones y tolerancia ...
Page 35: ...2 www AmericanHometec com service americanhometec com 1 800 295 8039 ...
Page 37: ...4 ...
Page 39: ...6 A Chauffe eau B Support de montage mural C Valve de décharge D Filtre pour prise d eau ...
Page 59: ...26 1 800 295 8039 2009 2010 American Hometec Inc AHQ B03X_v02a 072010 ...