american flame AFVK-SP Installation And Operating Instructions Manual Download Page 7

American Flame AFVK-SP Valve Kits

REV. 10-8-19 Page 7

INSTALLING BATTERIES INTO THE VALVE KIT BATTERY PACK

The battery pack is located at the back of the valve kit inside the metal box with the heat shield. See Fig. 14.

1.  The valve kits battery pack has a 6-inch, 4-pin wire harness connecting the battery pack to the module.  See Fig. 16.

2.  Prior to installation remove the battery pack during installation and install (4) AA batteries.

3.  Install the heat shield ovetop of the battery pack and slide it back into the back of the valve box. See Fig. 14.

Note:

 All valve kits are battery powered systems and will not operate without the battery pack. The battery pack controls 

the solenoid or motor drive in the system and provides the power necessary to operate each valve kit.  

AFVK-SP, AFVK-SP-HL, & AFVK-SP-MHL MODELS: 

The battery pack is located at the back of the valve kit inside the 

metal box with the heat shield. See Fig. 14. Install (4) AA alkaline batteries in the battery pack as shown in Fig. 15.

1.  The 6-inch, 4-pin male connector on the battery pack comes pre-installed to the 4-pin female connector located on the 

battery pack and module. 

Note

: Figs. 14 & 16 for reference.

2.  The AFVK-SP-HL & AFVK-SP-MHL also has (2) 18” wires (Red & Black) that are connected to the Hi/ Lo solenoid. 

Reference Figs. 11, 16 & 17.

3.  After the valve kit installation process is completed reinstall heat shield and battery pack back into the rear area of the 

metal box as shown in Fig. 14.

4.  Ensure the excess wire from the 4-pin wire harness and Hi/Lo wire harness are tucked in the metal box to protect 

them from heat.  

Requires (4) AA 1.5V

Alkaline Batteries

Batt

ery c

over

 slid

es o

n/off

La

tc

hin

g S

ole

no

id

D

C

 M

oto

r D

riv

e

Fig. 15

 Install (4) AA batteries into the battery pack.

Learn Button

(behind battery pack)

AFVK-SP BACK VIEW

Battery Pack

(4-Pin Connector 

into module)

Battery Pack

(shown as dotted line 

in front of module)

C

on

tr

ol M

odule

G

as V

alv

e

Gas Outlet

Pilot Tube

 Connection

Gas Inlet

Fig. 14 

Battery pack location.

4-Pin Connector

Red & Black Wires

BACK OF BATTERY PACK

Screw Terminals 

(secure red & black wires)

Latching Solenoid

DC Motor Drive

Black

Red

Wires attach to 

Solenoid or 

Motor Drive

Fig. 16

  4-pin connector on back of battery pack.

Fig. 17

 Red & Black wires out out of battery pack.

Summary of Contents for AFVK-SP

Page 1: ...tice Please leave these instructions for the consumer Retain for future reference Models AFVK SP AFVK SP HL AFVK SP MHL Electronic Safety Pilot System for Vented Gas Logs IF YOU CANNOT READ OR UNDERST...

Page 2: ...Set Page 5 Reference Section Wiring Diagram Page 6 Battery Pack Preparation Page 7 Gas Conversion Page 8 Operation of System Page 9 10 Troubleshooting Page11 Replacement Parts Page 12 Warranty Page12...

Page 3: ...Solenoid ON Remote Switch Continious Pilot On Off Switch AFVK SP HL Side View inside box Fig 4 AFVK SP HL Hi Lo Solenoid SP1001HL trans mitter damper clamp flex line adapter fitting includes battery p...

Page 4: ...et gas supply 9 Bend 12 stainless flex line and connect it to the valve outlet then connect other end to 3 8 flare fitting to existing burner pan Caution Ensure no gas line inlet or outlet are placed...

Page 5: ...ilot tubing from pilot assembly until the bottom of the pilot bracket is resting against the pan This will hold the pilot at the 45 position Use caution when bending pilot tubing not to kink the tubin...

Page 6: ...itor Wires Fig 11 Module Identification IN PILOT OUT PILOT ADJ MAIN MAIN 2 Pin Connector Green White Wires PILOT 2 Pin Connector Orange White Wires Pilot Ass y Fig 12 Gas Valve Identification OUT PILO...

Page 7: ...r on the battery pack comes pre installed to the 4 pin female connector located on the battery pack and module Note Figs 14 16 for reference 2 The AFVK SP HL AFVK SP MHL also has 2 18 wires Red Black...

Page 8: ...ROPANE it will be necessary to use the LPK 18 or LPK 24 1 The AFVK SP AFVK SP HL or AFVK SP MHL electronic control valves are convertible from Natural gas to Propane gas by simply turning the stem kno...

Page 9: ...OFF OFF REMOTE ON OFF CONTINUOUS PILOT Fig 20 Valve box switches Fig 21 Remote control Continuous button 2 REMOTE CONTROL FEATURE The AFVK SP AFVK SP HL or AFVK SP MHL comes with a remote control tra...

Page 10: ...ilot is lit 2 seconds the main burner will light 3 Adjust the main flame from HI to LO with the manual HI LO knob on front of valve kit Note Move the OFF REMOTE slide switch on the face plate of valve...

Page 11: ...e continuous pilot switch to the OFF position MAIN BURNER DOES NOT COME ON WHEN THE MANUAL ROCKER SWITCH OR REMOTE CONTROL IS TURNED ON 1 Confirm that the pilot sparks and lights 2 Check the 2 pin pla...

Page 12: ...tinuous Pilot Off On AUX OUT PILOT ADJ IN MAIN PILOT 10 11 LIMITED WARRANTY American Flame warrants the AFVK SP AFVK SP HL or AFVK SP MHL Valve Kit for 12 months from the date of purchase or installat...

Reviews: