![american flame AFVK-SP Installation And Operating Instructions Manual Download Page 2](http://html1.mh-extra.com/html/american-flame/afvk-sp/afvk-sp_installation-and-operating-instructions-manual_2924472002.webp)
American Flame AFVK-SP Valve Kits
REV. 10-8-19 Page 2
DESCRIPTION:
This installation manual covers three valve kits; AFVK-SP, AFVK-SP-HL and AFVK-SP-MHL.
Installation is the same for all of the kits however the operation is slightly different. All valve kits are fire tested at the
factory to ensure proper operation. Each kit is supplied with a individual rocker switch to enable ON/OFF operation
without the transmitter (if needed) and the ability to have continuous pilot or intermittent pilot ignition (IPI), which only
operates the pilot when the log set is turned ON. See each kit below and their contents.
Table of Contents
Description & Contents
Page 2
Valve Kit Models
Page 3
Installing into a Pre-Existing Log Set
Page 4
Installing with a New Log Set
Page 5
Reference Section & Wiring Diagram
Page 6
Battery Pack Preparation
Page 7
Gas Conversion
Page 8
Operation of System
Page 9-10
Troubleshooting
Page11
Replacement Parts
Page 12
Warranty
Page12
INSTALLER:
Each valve kit is supplied with a (UR3-68) adapter that provides an option
to convert the inlet or outlet gas connection from 3/8" flare fitting to a 1/2" flared fitting.
Simply thread the UR3-68 on to the inlet/outlet gas flared fitting as shown in Fig. 1.
Note
: No pipe joint compound or thread tape is necessary. Ensure fittings are tight and
test for gas leaks.
Top View
(Back of Valve)
Inlet
UR3-68
Fig. 1
Installing UR3-68 to the
inlet or outlet side of gas valve
ON
OFF
HI
LO
PILOT
Continuous
La
tching S
olenoid DC M
ot
or Dr
iv
e
ON
ON/OFF
Continuous Pilot
OFF
1
2
3
4
5
6
7
8
9
Fig. 2
Carton contents:
1
- Valve Kit
2
- Pilot Assembly
3
- Battery Pack Heat Shield
4
- Battery Pack
5
- Flex Connector
6
- Damper Clamp
7
- Adapter Fitting
8
- SP1001HL
9
- SP1001