american flame AFVK-SP-H/L-SPLIT Installation And Operating Instruction Download Page 7

American Flame AFVK-SPLIT VALVE KITS 

REV 12-27-13  Page 7 of 9

 

Continuous Pilot Button on the Hand Held Remote 

  

 

 

 

    

  

   

To use the Continuous Pilot feature from the hand held remote control ensure the “Off/Remote” switch on the front of the 

Switch Box is in the “remote” position (See figure 15). Simply press the button on the hand held remote marked 

“Continuous Pilot” (See figure 16). The pilot will immediately spark to light the pilot and the pilot will remain ON.

2. REMOTE CONTROL FEATURE:

NOTE

: All Valve Kits come with a remote control transmitter. 

The Switch Box electronic module has a built in remote control receiver that allows the user to pro-

gram a hand held remote transmitter to the appliance at any time during or after installation of the 

appliance.

1. 

There is a rocker switch located on the front of the Switch Box (See Figure 15). 

2. 

When the Remote/Off switch is in the OFF position the Switch Box will operate from the front 

 

mounted rocker switch (See figure 15).  

NOTE

: “O” is Off and “I” is for Ignite. 

3. 

When the Remote/Off switch is in the REMOTE position the appliance will operate from the

 

Remote Control transmitter. 

NOTE

: The Switch Box module must be programmed to the 

 

Remote transmitter.

4. 

To program the module; ensure the batteries have been installed in the battery pack and 

 

battery pack is removed from Switch Box.  Locate the learn button on the module (See 

 

figure 18). Press and release the learn button with a pen. There will be a beep sound from 

 

the module. Then press any key on the remote transmitter. Once the modules internal receiver

 

accepts the transmitter code, there will be a series of rapid beeps. Then remote system is 

 

ready for use.

Fig. 16  

SP1001 Transmitter

MAINTENANCE OF YOUR AFVK-SP-SPLIT SERIES VALVE KIT SYSTEM

 

1. 

Your system should be checked once a year (at the start of the heating season) for proper operation by a 

 

qualified service representative.

2. 

Replace all batteries at the start of the season. Items to check:  electronic valve operation, Spark to pilot 

 

operation, ON/OFF switch operation, damper operation, visual check of the burner and gas connections for leaks.

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR  EXPLOSION MAY RESULT 

CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

1. 

This installation should be installed with provisions for combustion and ventilation air, must conform with local 

 

codes or in the absence of local codes to the national fuel Gas Code ANSI Z223 latest addition.

2. 

This product must be on a gas supply line that is less than 1/2 psi. and an individual manual shut-off.

3. 

Never operate this new system with the glass fireplace enclosures (doors) in the closed position.

4. 

Connecting 110-volt electrical power to this product directly will cause damage and will void warranty.

ON

OFF

Continuous Pilot

ON/OFF

Lear

n Butt

on

AU

X

POWER

PEN

MODULE

INSIDE 

SWITCH BOX

Fig. 17

 Learn button on module

Summary of Contents for AFVK-SP-H/L-SPLIT

Page 1: ...for additional information consult a qualified installer service agency or gas supplier FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not try to light the appliance Do not touch any electrical switc...

Page 2: ...ottom of the pilot bracket is resting against the pan This will hold the pilot at the 45 position Use caution when bending pilot tubing not to kink the tubing and when locating the igniter and flame s...

Page 3: ...nlet Flex Line Fig 2 Basic installation layout centering the grate and components inside the firebox NOTE This diagram is strictly showing general layout and not to be used for clear ance purposes Ame...

Page 4: ...tor Blue White Wires Pilot Ass y Fig 5 Gas Valve Identification Fig 6 Module Identification American Flame AFVK SPLIT VALVE KITS REV 12 27 13 Page 4 of 9 5 Bend inlet gas supply line and connect the 3...

Page 5: ...1 NOTE On the AFVK SP SPLIT the battery pack switch can be placed in either position because the red and black wires are removed and not required for this system Because this kit has a manual flame he...

Page 6: ...er will now point to LP and the shaft will stay recessed inward 4 To convert the valve back to the factory setting NAT push in the rotary knob and rotate back to NAT NOTE the marker will now point to...

Page 7: ...See figure 18 Press and release the learn button with a pen There will be a beep sound from the module Then press any key on the remote transmitter Once the modules internal receiver accepts the tran...

Page 8: ...set turn the rocker switch OFF then ON or push the OFF button on the remote transmitter then push the ON button TROUBLESHOOTING CAUTION An experienced qualified service technician should only perform...

Page 9: ...er Allows system to operate without batteries OPTIONAL ACCESSORIES American Flame AFVK SPLIT VALVE KITS REV 12 27 13 Page 9 of 9 Limited Warranty American Flame warrants the AFVK SP SPLIT VALVE KIT SY...

Reviews: