American Flame AFVK-SPLIT VALVE KITS
REV 12-27-13 Page 7 of 9
Continuous Pilot Button on the Hand Held Remote
To use the Continuous Pilot feature from the hand held remote control ensure the “Off/Remote” switch on the front of the
Switch Box is in the “remote” position (See figure 15). Simply press the button on the hand held remote marked
“Continuous Pilot” (See figure 16). The pilot will immediately spark to light the pilot and the pilot will remain ON.
2. REMOTE CONTROL FEATURE:
NOTE
: All Valve Kits come with a remote control transmitter.
The Switch Box electronic module has a built in remote control receiver that allows the user to pro-
gram a hand held remote transmitter to the appliance at any time during or after installation of the
appliance.
1.
There is a rocker switch located on the front of the Switch Box (See Figure 15).
2.
When the Remote/Off switch is in the OFF position the Switch Box will operate from the front
mounted rocker switch (See figure 15).
NOTE
: “O” is Off and “I” is for Ignite.
3.
When the Remote/Off switch is in the REMOTE position the appliance will operate from the
Remote Control transmitter.
NOTE
: The Switch Box module must be programmed to the
Remote transmitter.
4.
To program the module; ensure the batteries have been installed in the battery pack and
battery pack is removed from Switch Box. Locate the learn button on the module (See
figure 18). Press and release the learn button with a pen. There will be a beep sound from
the module. Then press any key on the remote transmitter. Once the modules internal receiver
accepts the transmitter code, there will be a series of rapid beeps. Then remote system is
ready for use.
Fig. 16
SP1001 Transmitter
MAINTENANCE OF YOUR AFVK-SP-SPLIT SERIES VALVE KIT SYSTEM
1.
Your system should be checked once a year (at the start of the heating season) for proper operation by a
qualified service representative.
2.
Replace all batteries at the start of the season. Items to check: electronic valve operation, Spark to pilot
operation, ON/OFF switch operation, damper operation, visual check of the burner and gas connections for leaks.
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
1.
This installation should be installed with provisions for combustion and ventilation air, must conform with local
codes or in the absence of local codes to the national fuel Gas Code ANSI Z223 latest addition.
2.
This product must be on a gas supply line that is less than 1/2 psi. and an individual manual shut-off.
3.
Never operate this new system with the glass fireplace enclosures (doors) in the closed position.
4.
Connecting 110-volt electrical power to this product directly will cause damage and will void warranty.
ON
OFF
Continuous Pilot
ON/OFF
Lear
n Butt
on
AU
X
POWER
PEN
MODULE
INSIDE
SWITCH BOX
Fig. 17
Learn button on module