INSTALLATION: VALVE KIT WITH A NEW LOG SET

1. 

Make sure gas is completely turned 

OFF

 to the fireplace. Make sure you have a certified and approved shut-off    

 

within 6-feet of the fireplace, or per the local code requirements.

2. 

Follow the instructions supplied with the log set to locate the burner pan. Using the fittings, orifice and gas supply

 

line that came with the log set. Connect the line to the inlet gas supply.

3. 

Locate a position on the back of the burner pan about 4” from the right or left side of the burner pan. 

 

(See figures 3 & 4)

4. 

Mount pilot assembly to burner pan as shown in (Figure 3). 

NOTE

: This pilot bracket clips on the burner

 

pan and holds the pilot at a 45

°

 position onto the pan, an attachment screw is recommended. Bend pilot tubing 

 

from pilot assembly until the bottom of the pilot bracket is resting against the pan. This will hold the pilot at the 45º 

 

position. (Use caution when bending pilot tubing not to kink the tubing and when locating the igniter and flame 

 

sensor wires not to locate the wires and the tubing in or over the burner pan.)  Locate the Valve Box on the left

 

front corner and the Switch Box in the right front corner of the firebox as far forward as possible (See Figure 4).

Burner Pan

Basket Grate

G

as 

Valv

e B

ox

Swit

ch B

ox

Hi-Temp Wiring

Harness

Pilot Tubing

Pilot Ignition

Wires

Gas Inlet & 

Flex Line

Fig. 2

 Basic installation layout centering the grate and   

components inside the firebox. 

NOTE

: This diagram is 

strictly showing general layout and not to be used for clear-

ance purposes.

American Flame AFVK-SPLIT VALVE KITS 

REV 12-27-13  Page 3 of 9

8. 

Connect inlet supply line to the 3/8” flare fitting on the gas valve. (If using aluminum tubing use caution 

 

not to kink the aluminum tube when bending to attach to the valve).

9. 

Bend 12” stainless flex line (supplied with new kit) and connect to valve outlet. Next connect other end to 3/8” flare 

 

fitting on burner pan, 

 

CAUTION: Do not let inlet gas line to the valve kit or gas outlet line from the valve kit be placed inside or 

 

overtop of the burner pan.  ENSURE HI-TEMP WIRING HARNESS, PILOT ASSEMBLY IGNITION WIRES

 

AND PILOT TUBING ARE LOCATED BEHIND THE BURNER PAN; NOT BURIED UNDER THE SAND AND    

 

NOT IN THE PATH OF THE FLAME.

10. 

Turn gas supply 

ON

 and check all connections for leaks using soapy water solution before lighting the log set.

11. 

Follow valve lighting instructions. After the pilot is operating, check 

ALL

 fittings for leaks.

12. 

Reinstall basket grate and logs.

13. 

Install Damper Clamp (supplied with valve kit) which allows damper to remain slightly open to allow the pilot

 

gases to vent). 

 

NOTE: For any PROPANE installations see conversion kit instructions.

Burner Pan

4.00”

Pilot Bracket

Optional

  Screw

Fig. 3

 Pilot Bracket Installation

Valve Box Location

Switch Box Location

2” Min.

2” Min.

2” Min.

2” Min.

Burner Pan

Basket Grate

Fig. 4

 Minimum Clearances From Basket Grate

Summary of Contents for AFVK-SP-H/L-SPLIT

Page 1: ...for additional information consult a qualified installer service agency or gas supplier FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not try to light the appliance Do not touch any electrical switc...

Page 2: ...ottom of the pilot bracket is resting against the pan This will hold the pilot at the 45 position Use caution when bending pilot tubing not to kink the tubing and when locating the igniter and flame s...

Page 3: ...nlet Flex Line Fig 2 Basic installation layout centering the grate and components inside the firebox NOTE This diagram is strictly showing general layout and not to be used for clear ance purposes Ame...

Page 4: ...tor Blue White Wires Pilot Ass y Fig 5 Gas Valve Identification Fig 6 Module Identification American Flame AFVK SPLIT VALVE KITS REV 12 27 13 Page 4 of 9 5 Bend inlet gas supply line and connect the 3...

Page 5: ...1 NOTE On the AFVK SP SPLIT the battery pack switch can be placed in either position because the red and black wires are removed and not required for this system Because this kit has a manual flame he...

Page 6: ...er will now point to LP and the shaft will stay recessed inward 4 To convert the valve back to the factory setting NAT push in the rotary knob and rotate back to NAT NOTE the marker will now point to...

Page 7: ...See figure 18 Press and release the learn button with a pen There will be a beep sound from the module Then press any key on the remote transmitter Once the modules internal receiver accepts the tran...

Page 8: ...set turn the rocker switch OFF then ON or push the OFF button on the remote transmitter then push the ON button TROUBLESHOOTING CAUTION An experienced qualified service technician should only perform...

Page 9: ...er Allows system to operate without batteries OPTIONAL ACCESSORIES American Flame AFVK SPLIT VALVE KITS REV 12 27 13 Page 9 of 9 Limited Warranty American Flame warrants the AFVK SP SPLIT VALVE KIT SY...

Reviews: