american flame AFVK-SP-H/L-SPLIT Installation And Operating Instruction Download Page 6

Top View LP Conversion 

Top View NAT Conversion 

IN

PILOT

OUT

PILOT ADJ

MAIN

Aluminum Cap

IN

PILOT

OUT

PILOT ADJ

MAIN

NAT

NAT

LP

LP

Fig. 12

 Removing aluminum cap from valve

Detail View Under

 

Cap

Fig. 13

 Gas Valve LP View

Fig. 14

 Gas Valve NAT View

American Flame AFVK-SPLIT VALVE KITS 

REV 12-27-13  Page 6 of 9

CONVERTING VALVE KITS FROM NATURAL TO LP (PROPANE) GAS

NOTE

:  When converting a vented log set from NATURAL to LP (PROPANE) it will be necessary to use the LPK-18 or 

LPK-24.  The LPK-18 is used for 18-inch or smaller logs sets and the LPK-24 is used for 24 to 30-inch log sets.

The 

AFVK-SPLIT VALVE SYSTEMS

 use electronic control valves that are convertable from Natural to LP gas by a 

Simple Rotary Knob 

located on the front 

“face”

 of the gas valve (See figure 13).

1. 

Remove the black metal cover from the front of the Valve Box to access the 

“face”

 of the control valve.

2. 

Unscrew the aluminum cap on the front of the gas valve (See figure 12).  Note

 

the position of the marker on top

 

of the rotary knob shaft. This mark will point to NAT or LP indicating the type of gas the valve is currently set.

3. 

To convert the valve from the factory setting (NAT) gently push the rotary knob inward with two fingers and rotate

 

left or right to the LP position (See figure 13).  

NOTE

: The marker will now point to LP and the shaft will stay 

 

recessed inward.

4. 

To convert the valve back to the factory setting (NAT) push in the rotary knob and rotate back to NAT.  

NOTE

: the

 

marker  will now point to NAT and the shaft will remain in the outward position.

5. 

After the conversion has been made check the outlet pressure with a manometer (main burner must be ON).

 

The factory setting on the internal regulator is 3.5”WC Natural and 10.5”WC LP.

6. 

Replace the aluminum cap.

NOTE

: See the LPK-18 or LPK-24 instructions to convert the burner pan to LP gas this involves installing an orifice air 

shutter, pilot orifice and media (removing sand and using vermiculite for LP gas).

SPECIAL FEATURES OF THE VALVE KIT ELECTRONIC MODULE

All valve kits modules have (2) special features built into the system as follows:

1. CONTINUOUS PILOT FEATURE: 

The AFVK-SPLIT valve kits have a Continuous Pilot feature that may be activated in cold 

climate conditions or to maintain a draft in the chimney. The continuous pilot can be activated 

by the following two methods.

 

Off/Continuous Pilot Switch on Front of the Switch Box

The Continuous Pilot feature may be activated by placing the ”Off/Continuous Pilot” switch 

located on the front of the Switch Box in the “Continuous Pilot” position. See figure 15. When 

this switch is turned to the Continuous pilot position the pilot will immediately spark to light the 

pilot and the pilot will remain ON.

OFF

REMOTE

CONTINUOUS

PILOT ON

OFF

Fig. 15

 Module Switches

Summary of Contents for AFVK-SP-H/L-SPLIT

Page 1: ...for additional information consult a qualified installer service agency or gas supplier FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not try to light the appliance Do not touch any electrical switc...

Page 2: ...ottom of the pilot bracket is resting against the pan This will hold the pilot at the 45 position Use caution when bending pilot tubing not to kink the tubing and when locating the igniter and flame s...

Page 3: ...nlet Flex Line Fig 2 Basic installation layout centering the grate and components inside the firebox NOTE This diagram is strictly showing general layout and not to be used for clear ance purposes Ame...

Page 4: ...tor Blue White Wires Pilot Ass y Fig 5 Gas Valve Identification Fig 6 Module Identification American Flame AFVK SPLIT VALVE KITS REV 12 27 13 Page 4 of 9 5 Bend inlet gas supply line and connect the 3...

Page 5: ...1 NOTE On the AFVK SP SPLIT the battery pack switch can be placed in either position because the red and black wires are removed and not required for this system Because this kit has a manual flame he...

Page 6: ...er will now point to LP and the shaft will stay recessed inward 4 To convert the valve back to the factory setting NAT push in the rotary knob and rotate back to NAT NOTE the marker will now point to...

Page 7: ...See figure 18 Press and release the learn button with a pen There will be a beep sound from the module Then press any key on the remote transmitter Once the modules internal receiver accepts the tran...

Page 8: ...set turn the rocker switch OFF then ON or push the OFF button on the remote transmitter then push the ON button TROUBLESHOOTING CAUTION An experienced qualified service technician should only perform...

Page 9: ...er Allows system to operate without batteries OPTIONAL ACCESSORIES American Flame AFVK SPLIT VALVE KITS REV 12 27 13 Page 9 of 9 Limited Warranty American Flame warrants the AFVK SP SPLIT VALVE KIT SY...

Reviews: