background image

 

4

INSTALLATION AND OPERATION INSTRUCTIONS 

 

INTRODUCTION 

 

Thank you for purchasing your American Fibertek Series 8485 multimode four channel 
video multiplexer with bi-directional data. Please take a few minutes to read these 
installation instructions in order to obtain the maximum performance from this product. 
 
 

FUNCTIONAL DESCRIPTION 

The 8485 Series units operate as a transmitter / receiver pair for the transmission of four 
simultaneous, real time baseband NTSC/PAL video signals with field configurable bi-
directional data over a single multimode fiber optic cable.  
 
This link can accommodate either a single RS485 interface (2 or 4 wire) or both an 
RS422 and RS232 interface. When used in RS422/RS232 mode, each interface 
functions independent of the other. 

These units are factory shipped configured in the 

RS485 (4 wire) configuration.      

 
The MTX-8485 transmitter accepts four video inputs and multiplexes these signals along 
with the data signals onto a single optical output port for connection to the fiber 
transmission system. Correspondingly, the MRX-8485 receiver converts the optical 
signal to four independent video output signals along with the data signals. 
 
The 8485 Series units operate on 50 um or 62.5 um multimode fiber. Refer to the data 
sheets for detailed performance specifications. 
 
The individual units may be configured for rack mounting or wall mounting depending 
upon the position of the included mounting hardware. 

 
INSTALLATION 

THE INSTALLATION OF THESE UNITS SHOULD BE MADE BY A QUALIFIED 
SERVICE PERSON(S) AND MUST CONFORM TO ALL LOCAL CODES.  
 
To install the MTX-8485 or MRX-8485 it is first necessary to mount the rack flanges to 
the unit. 
 
For rack mounting the ears are installed on the 
sides of the unit with the surfaces that have 
oval holes flush with the front of the unit as in 
Figure 1. Mount the ears with the #10 flathead 
screws provided. To mount in the rack cabinet, 
use mounting screws that are appropriate for 
the rack cabinet being used. 
 
 
 

Summary of Contents for MRX-8485

Page 1: ...Copyright 2003 American Fibertek Inc 0530JD Instruction Manual MTX 8485 MRX 8485 Four Channel Video Multiplexer with Bi directional Data...

Page 2: ...2 Table of Contents...

Page 3: ...r Source 5 Power Connection 5 Input Output Connections 5 Data Configuration 6 MTX 8485 Status LED Indicators 8 MRX 8485 Status LED Indicators 9 Data Termination Requirements 10 Offset Bias RS485 Data...

Page 4: ...s and multiplexes these signals along with the data signals onto a single optical output port for connection to the fiber transmission system Correspondingly the MRX 8485 receiver converts the optical...

Page 5: ...iber optic connection is made via a ST connector located at the back of the unit Be sure to allow sufficient room for the required minimum bend radius of the fiber cable used Video input and output co...

Page 6: ...RS422 data channel or 3 1 bi directional RS232 data channel or 4 1 bi directional RS232 data channel and 1 bi directional RS422 data channel These units are factory shipped configured for RS485 4 wire...

Page 7: ...hes that identifies the specific switch function and up down direction for RS485 transmission The following is an illustration of the data configuration switches that identifies the specific switch fu...

Page 8: ...ion Protocol DATA 1 TX DATA 1 RX DATA 2 TX DATA 2 RX RS485 Configuration RS485 Tx RS485 Rx Hi Z Hi Z RS422 Configuration RS422 Tx RS422 Rx Not Used Not Used RS232 Configuration Not Used Not Used RS232...

Page 9: ...Tx and Rx LEDs The data channels associated with these front panel DATA LEDs are listed below Configuration Protocol DATA 1 TX DATA 1 RX DATA 2 TX DATA 2 RX RS485 Configuration RS485 Tx RS485 Rx Hi Z...

Page 10: ...s multiple transmitter devices to reside on the same wire pair The software must dictate a protocol that allows one device to transmit at any one time to prevent data crashes Data wiring can use two w...

Page 11: ...will cause communications to fail Offset bias for two wire RS485 can be applied on the MTX 8485 and MRX 8485 by setting switch 4 and switch 6 down Please note that these switches work as a set and mu...

Page 12: ...ent consequential or incidental damages No agreement or understanding expressed or implied except as set forth in this warranty will be binding upon American Fibertek unless in writing signed by a dul...

Reviews: