The Magnum 7500 Corn and Wood Pellet Furnace comes standard with a combustion enhancement
system built into the firepot. This system enables the unit to perform efficiently and reduces ash, fly-ash
on the outside of the home and directs more heat to your home.
It is important that whenever operating the Magnum 7500 that the CES is in place. You can however
remove the CES for cleaning, maintenance and startup of the fire.
When starting the fire take the scraper tool (provided) and hook it into the top of the CES and Remove.
Be careful not to burn yourself or set the hot CES on a combustible surface.
After you have lit the fire and the fire is established you can place the CES back on the firepot and the fire
will start quicker.
NOTE: the fire may not be coming out the top of the CES right away but you will be able to see a glow
indicating that the fire is burning. If you do not see any fire glow, remove the CES and check the fire.
It is important to always clean the surface area that the CES sits on. If the surface area is not clean, fire
will come out between the CES and the firepot. This will not cause damage or problems but will not
allow the CES to work efficiently.
COMBUSTION ENHANCEMENT SYSTEM (CES)
Firepot and
cradle
Combustion
enhancement system
(CES)
Place scraper tool in front tab and
remove the CES