background image

VIEW MANAGER 96 ENHANCED TOUCH TRACKER  

8000-0748-02, REV. B1 

INSTALLATION INSTRUCTIONS

 

3 of 6 

 

Installing Enhanced Touch 
Trackers 

Installation Kit (0351-0474-01): 

Description 

 Quantity Part 

Number 

CABLE ASSY,MDLR,RJ-45,8 COND,14    1 

6003-0047-01  

SCR,THD CUT,M2.9X9.5,PHP,ST,Z,  

1  

5899-0004-102 

ANCHOR,PLASTIC,#4-#8,3/4"   

2  

2880-0083-01  

SCR,TYP AB,PHP,CAD,#8X1"  

2  

2816-7634-44  

CONN,PLUG,TUBLR,.200CTR,26-12A 

1  

2109-0254-04  

LUG,SPADE,CRIMP,INSUL,22-16AWG  

3  

2141-0002  

CABLE,3COND,18AWG,PVC   

16.50 ft 

6002-0024-01  

INTERCONNECT BOX,TOUCH TRACK   1  

0300-1000-01  

 

 

 

WARNING—RISK OF ELECTRIC 
SHOCK! 

Disconnect AC power to the VM96 
System and External Interconnect 
Module before starting to install this 
equipment. Failure to do so could 
shock you and may damage the VM96 
system or attached devices. 

 

 

CAUTION—ELECTROSTATIC 
SENSITIVE DEVICE! 

Follow proper handling procedures to 
prevent component failure. 

 
1.  Review the network design to determine which 

Touch Tracker controllers (controller) must be 
terminated. Set jumper E1 on EIMs requiring 
termination (Figure 6).  

2.  Mount each EIM on a wall or other surface 

within 3m (10') of its attached controller. Then 
route a twisted-pair SensorNet cable from the 
VM96 console, past each EIM, until the last 
EIM is reached. Do not cut the cable at each 
EIM. 

3.  Referring to Figures 6 through 8: 

a.  Wire each EIM’s power supply leads to 

pins 2, 3, and 4 of a 5-pin compression 
connector (one connector per EIM). Tighten 
the fastening screws to secure the wires. 

b.  Strip 25mm (1") of outer insulation from the 

SensorNet cable at each EIM location. 
Then strip 12mm (.5") of insulation from 
each wire. 

c.  Bend the two wires in the middle of the 

stripped area. Insert one wire into pin 1, 
and the other into pin 5 of the EIM's 5-pin 
compression connector. Tighten both 
fastening screws to secure the wires. 

d.  After attaching power and SensorNet 

cables, plug the wired 5-pin connector into 
each EIM's WAG005 connector. See Figure 
6. 

e.  Connect the EIM SensorNet cable to the 

SensorNet card or preceding SensorNet 
device. Then connect the cable between 
the last EIM and the next SensorNet 
device. 

f.  Plug the modular interconnect cable into 

the RJ-45 connector on the back of the 
Touch Tracker controller. Use the strain 
relief. Plug the other end into the EIM. 

 

 

Figure 6: EIM Board Layout. 

 

3 2 1

J1

J2

J3

A

SSY

 

03
01

-0

3

40

-0

1 R

E

V

-

E1

1-2 TERMINATED

2-3 UNTERMINATED

3 2 1

 

 
 
 

Figure 7: Installing one Touch Tracker. 

 

J3

J2

2 1

3

4

5

P1

J2

1

2

3

4

 

Terminated

Power & SensorNet 

Connector - WAG005

Touch Tracker Connector

RJ-45

RS-232 connector 

DB-9(F)

T

OUCH 

T

RACKER

 

Power 

Supply 

SensorNet 

Link 

VM96 card, 

J-Box link, 

or other 

SensorNet 

device 

SensorNet A 
SensorNet B 

24Vac A
Ground 
24Vac B

RJ-45 Cable