![American Dynamics Version 4.3 Software Update 3 Release Notes Download Page 8](http://html1.mh-extra.com/html/american-dynamics/version-4-3-software-update-3/version-4-3-software-update-3_release-notes_2924306008.webp)
Intellex 4.30 Software Update 3 Release Notes
7
8200-2640-28 A1
Bosch VG4-500i Boot-up Times
Bosch VG4-500i models are large outdoor domes, and these have been known to take up to 3-5
minutes to finalize base checks internally and heat the pressurized dome. If powered up at the
same time as Intellex, then the Intellex system will have already started in its running state and
may not have registered the PTZ functionality (depending on how far the camera has powered on
before Intellex was ready). For those cases where the camera has not registered properly, you
can delete the camera entry and add it again (giving the camera an assignment slot) when the
camera is fully powered up and available, and then adding the PTZ capability.
Bosch IP VG4-500i Messages
When creating a preset on the Bosch VG4-500i you will see a confirmation message that must be
acknowledged before the preset is stored on the camera (see Figure 2). This functionality is
coded on the camera itself.
1. To acknowledge this message, exit from the presets on screen display controls and
select the Iris control for “Yes” or Focus Control for “No” and preset will be stored.
2. Repeat this process for each preset required.
Figure 2: Confirmation Message