Configuring Alarms, Areas, Home, Privacy Settings, and Presets
4-15
The boundary points on the Privacy Zone are selected by pressing
Zoom
. Once a boundary
point is selected, the arrows “blink” until the target area is moved to a valid area. Once the
target moves to a valid area, the arrows stop blinking. If you move the target more than 90-
degrees from a selected point, the arrows begin to blink again, indicating that the boundary is
too large.
If you attempt to establish a boundary point while the arrows are blinking you will receive an
error message:
Zone is Too Small
or
Zone is Too Large
. If this happens, you must start
programming from the beginning. Pressing
Focus Far
returns you to the Privacy Zone
programming screen.
If you attempt to program more than eight Privacy Zones, the following message appears:
Maximum Allowed Number of Zones Defined
Pressing
Focus Far
returns to the
Program Privacy Zones
screen. To program a new
zone, you must delete at least one of the eight existing Privacy Zones. See
I M P O R T A N T
Areas of the Privacy Zone may be exposed during rapid pan / tilt movements of the dome. To
compensate for this limitation, you may want to program the Privacy Zone to be 20 to 25%
larger than the area you want to mask.
Programming Privacy Zones
1. Select
Alarms/Areas/Home/Presets/PZ
from the
Dome Configuration Menu
.
2. Select
Privacy Zones
.
3. The Program Privacy Zones screen appears. Select
Add Privacy Zone
.
4. Use
the
Pan/Tilt
control to position the arrows over the boundary point. Press
Zoom
to
create.
5. Repeat step 4 to create boundary points 2 and 3.
Tip:
Remember, if the arrows are blinking, you are not in a valid target
area. Only select a point if the arrows are not blinking.
6. After the third boundary point is created, the fourth boundary point is automatically
calculated. The new Privacy Zone appears on the screen. To program additional Privacy
Zones, repeat steps 3 through 5. When finished, continue with step 7.
7. Select
Exit
to return to
Alarms/Areas/Home/Presets/PZ
screen.
8. When
the
Alarms/Areas/Home/Presets/PZ
screen appears, select
Exit
. The
Dome
Configuration Menu
appears. Continue with
Summary of Contents for SpeedDome Ultra VII
Page 1: ...8200 0184 02 B SpeedDome Ultra VII 22x Camera Dome Configuration Utility Operator s Manual ...
Page 2: ......
Page 10: ...viii SpeedDome Ultra VII Operator s Manual N O T E S ...
Page 18: ...1 8 SpeedDome Ultra VII Operator s Manual N O T E S ...
Page 26: ...2 8 SpeedDome Ultra VII Operator s Manual N O T E S ...
Page 110: ...Glossary 4 SpeedDome Ultra VII Operator s Manual N O T E S ...
Page 112: ...Index 2 SpeedDome Ultra VII Operator s Manual N O T E S ...
Page 113: ......