![American Dynamics SpeedDome LT Installation And Service Manual Download Page 24](http://html.mh-extra.com/html/american-dynamics/speeddome-lt/speeddome-lt_installation-and-service-manual_2924108024.webp)
INDOOR INSTALLATION
SPEEDDOME LT
2-9
!
WARNING!
Disconnect cable from power source
when performing cable conversions.
Figure Chapter 2-11. Patch cable connection
4. If it is necessary to replace the Cinch-Jones
connector on the composite and video
cables, use the male and female BNC and
compression-type connectors supplied with
the SpeedDome Cable Conversion Kit (0351-
0403-01—Figure Chapter 2-12).
Use the following table and figure for data cable pin
out information.
Connector Pin Outs
Cinch-Jones (P2)
Compression (P1)
Pin No. Wire Color
Signal Name
Pin No.
7
Brown
Data Out (Lo)
1
8
Yellow
Data Out (Hi)
2
3
Black AC
3
4
Red
Ground
4
5
White
AC
5
2
Green
Data In (Lo)
6
1
Orange
Data In (Hi)
7
Figure Chapter 2-12. Extending composite
cable
1
7
1
7
5. Set the dome address (Figure Chapter 2-13).
Using address switches (g), set the dome address
(Figure 2-13).
Figure Chapter 2-13. Setting dome address
0
0
1
1
9
9
MSB LSB
SW1
SW2
6. Lock the chassis into the housing.
Squeeze the ejector pins (h) and swing the chassis
all the way up, while easing the cables up through
the access holes. Release these pins into the
remaining corner receptacles.
!
WARNING!
Ejector pins must be fully inserted in
their receptacles.
J1
To Unicard
terminal block,
P3
Video
Board edge
To Cinch-Jones
connector on composite
Female compression-
type connector,
p/n 2109-0254-06
Male compression-type
connector, p/n 2109-
Female BNC connector,
p/n 2111-0034-01
Male BNC connector,
p/n 2111-0033-01
To Unicard BNC
connector, J1
To Unicard
To existing
J-Box
cables
To video cable
BNC connector