INDOOR INSTALLATION
SPEEDDOME LT
2-7
2. Connect the nipple to the pipe by using the
pipe tee (Figure Chapter 2-7).
Thread the straight pipe (c) (not supplied) and nipple
(d) into the pipe tee (e). Thread the nipple of the
entire assembly into the flange.
Figure Chapter 2-7. Pendant mount - exploded
view
3. Feed cables through a hole in the side of the
housing.
Feed video and multiconductor cables through
center hole of pipe tee and down through the pipe.
Note: Remove the Cinch-Jones connector, if used,
to enter pipe.
Slip the cap (f) onto the pipe, then thread housing
onto the pipe. The housing is now ready for chassis
installation (go to “Chassis Installation,” page 2-8).
Pendant (I-Beam) Mounting
This procedure explains how to mount the dome’s
housing to an I-beam in the ceiling. After com-
pleting this procedure, go to page 2-8 for chassis
installation.
Install Kit Supplied
0351-0391-01*
a) Base
plate
1
0500-3975-01
b) Clamp
plate
2
0500-3976-01
c)
Screw, mach. M6x70
4
5801-4194-311
d) Washer,
flat
12
5840-0500-020
e)
Washer, SL, M6
8
5846-0500-020
f)
Nut, hex, M6
8
5820-0500-020
g)
Flange, 1-1/4” dia.
1
1400-0069-01
h)
Nipple, short 1-1/4”x2”L
1
1417-0041-01
i)
Fitting, pipe tee, 1-1/4”
1
1417-0040-01
* Only parts used in this procedure are listed.
Procedure
1. I-beam attachment (Figure Chapter 2-8).
Set the base plate (a) against a suitable ceiling
member. Secure the plate using clamps (b) and
hardware supplied (c-f)—see base plate hole-to-hole
dimensions, below. Attach the flange (g) using
hardware supplied.
Figure Chapter 2-8. I-beam mount
90mm
(3.5")
128mm (5")
179mm (7")
230mm (9")
2. Vertical/horizontal mounting (Figure Chapter
2-9).
Thread nipple (h) and purchased part into the pipe
tee (i) and screw the entire assembly into the base.
Next, feed video and multiconductor cables through
center hole of pipe tee.
Note: Remove the Cinch-Jones connector, if used,
to enter pipe.
Finally, thread the housing onto the pipe. The
housing is now ready for chassis installation (go to
“Chassis Installation,” on the next page).
Figure Chapter 2-9. Vertical and horizontal
mountings
a
Base
Base plate hole-
to-hole
dimensions
Note: If replacing pipe tee with
pipe, cable exiting pipe tee must
be no farther than 15.2cm (6”)
from I-beam clamp.
Flange
Cables
b
Housing
d
Purchased
Part
Pipe
c-f
c
e
20M
(20’)
Ceiling
member
f
g
h
Cables
Housing
i
Hardware
supplied