background image

OPERATION

The following information is for general use of the AD2078

keyboard.  For use with a specific switching system, refer

to that system's Operating Instructions manual.

Keyboard control of switching system functions is, generally,
"monitor oriented".  A keyboard controls functions associated
with the the monitor to which it is "called".  System monitors
which are not under keyboard control continue to operate
under control of the switching system, independent of
keyboard actions.

See Figure 3, page 4, for the location and arrangement of the
keyboard displays and controls described in the following
sections.

A built-in test capability is provided in the AD2078 keyboard
to assist in determining faults in the software or hardware of
the keyboard.  See the Appendix, page A-2, for the built-in test
operating procedures.

Displays

Four LED displays are provided on the keyboard.

1. STATUS - This LED display shows the current status of the

connected switching system.  Refer to the system's
Operating Instructions manual for STATUS display details.
The STATUS display is three digits.

2. MONITOR - This display shows the number of the monitor

which the keyboard is currently controlling (the "called"
monitor).  The MONITOR display is five digits.

3. CAMERA - This display shows the number of the camera

(video input) currently being displayed on the called
monitor.  The CAMERA display is six digits.

4. ENTER - This display shows the numbers entered on the

numeric keypad by an operator in preparation for requesting
some action.  The ENTER display is four digits.  

Whenever a number appears in the ENTER display it
indicates that some action has been initiated but not
completed.  This action should be completed or the entry
cleared by pressing the CLEAR button before initiating any
new action.

STATUS Section Controls

F1, F2

The F1 and F2 buttons are special function buttons used to
perform certain actions which require double key actions.
Refer to the appropriate system's Operating Instructions
manual for further details on the use of these buttons.

The F1 button is also used in the setup procedures for the
AD2078 keyboard, see Setup, page 3.

USER

The USER button provides the means to enter a user
password or identification number for logging onto a
password-protected system.

SITE

The SITE button is used for selecting satellite camera sites in
systems with satellite site switching capability.  

Note:  For either the USER or the SITE button, refer to the

appropriate system's Operating Instructions manual for
further details on the applicability and operation of these
functions in each system installation.

KEYSWITCH

The keyswitch on the AD2078 keyboard front panel has
three positions.

OFF (Off) - This keyswitch position locks the user out from

the SET button in the PRESET section, the OFF, ARM,
and PROG buttons in the MONITOR section, and the
menu programming functions of the buttons in the
AUX/LENS section.  Key removal is possible only when
the key is placed in this position.

PROG (Program) - When the keyswitch is placed in this

position, the user has access to the SET button, the OFF
and ARM buttons, and the PROG button functions.  The
menu buttons can not be accessed in this keyswitch
position.

DISP (Display) - When the keyswitch is placed in the DISP

position, the main menu display of the Matrix Switching
System CPU is called up and the menu programming
buttons in the AUX/LENS section are enabled.

AD2078

OPERATION

5

Summary of Contents for AD2078

Page 1: ...ing procedures for the American Dynamics AD2078 System Keyboard AD2078 Series keyboards are used with American Dynamics Matrix Switching Systems for full system control and for programming and setup f...

Page 2: ...is furnished to the purchaser under a license for use on a single system Information furnished by SENSORMATIC is believed to be accurate and reliable However no responsibility is assumed by SENSORMATI...

Page 3: ...ed with the packing list with your order Be sure to save 1 The shipping cartons and insert pieces They are the safest material in which to make future shipments of the product 2 The IMPORTANT SAFEGUAR...

Page 4: ......

Page 5: ...ory Default 3 KEYBOARD LAYOUT 4 OPERATION 5 Displays 5 Status Section 5 Monitor Section 6 Camera Section 6 Aux Lens Section 7 Enter Keypad Section 7 Preset Section 7 APPENDIX Built In Test A 2 TYPICAL...

Page 6: ......

Page 7: ...MENU PROGRAMMING INSTALLATION This installation should be made by qualified service personnel and should conform to all local electrical codes Safeguards must be taken to avoid unintentional operatio...

Page 8: ...PU the AD2150 or the AD2350 For AD1650B AD2050 AD2150 or AD2350 connections where the distance is over seven feet only the J1 side of the HP0082 Terminal Block is used 1 Connect a three wire shielded...

Page 9: ...to step 6 below LED Brightness To exit the setup procedures at this point bypassing brightness and volume setups press the F1 button This action saves the new baud rate and returns the keyboard to nor...

Page 10: ...s numeric data for keyboard actions such as monitor camera or aux number CLEAR Clears data entered AUX LENS SECTION MENU PROGRAMMING Dual Function Buttons OFF Turns off a specified auxiliary ENTER Sto...

Page 11: ...hat some action has been initiated but not completed This action should be completed or the entry cleared by pressing the CLEAR button before initiating any new action STATUS Section Controls F1 F2 Th...

Page 12: ...nce NEXT or reverse LAST stepping through a camera program sequence or tour These buttons step through the sequence one camera at a time only when the sequence is in a HOLD or has been called to a spe...

Page 13: ...es entered data for menu functions EXIT Exits menu programming functions Refer to the appropriate system s Operating Instructions manual for information regarding menu programming ENTER KEYPAD Section...

Page 14: ......

Page 15: ...APPENDIX...

Page 16: ......

Page 17: ...e is manually advanced Push the TEST SWITCH button to advance to the Seven Segment LED test Seven Segment LED Test This test simultaneously illuminates each LED element of all 18 LED s for a brief int...

Page 18: ...itch positions When the test is started the ENTER display shows either OFF PROG or DISP representing the current keyswitch position and the STATUS display shows the number 0 1 or 2 respectively Rotate...

Page 19: ...TYPICAL SYSTEM CONNECTIONS...

Page 20: ......

Page 21: ...J2 Keyboard System JJ0007 Cable HP0082 TERMINAL BLOCK Jumper wires JJ0007 Cable XMIT GND RCD Connection shown where distances between keyboard and AD1650B are less than seven feet RS 232 1 2 3 4 J1 O...

Page 22: ...e JJ0007 Cable HP0082 TERMINAL BLOCK 3 wire shielded Belden 8770 or equivalent 5 4 6 3 2 7 1 8 J1 J2 XMIT GND RCD Connection shown where distances between keyboard and AD1650B are over seven feet RS 2...

Page 23: ...HZ 1 5 4 6 3 2 7 8 5 4 6 3 2 7 1 8 J1 J2 Keyboard System JJ0007 Cable Connection shown where distances between keyboard and AD1996 controller are less than seven feet HP0082 TERMINAL BLOCK C 4 Wall Tr...

Page 24: ...own where distances between keyboard and AD1996 are over seven feet C 5 AD2078 HP0047 TERMINAL BLOCK 1 2 3 4 5 6 7 8 JJ0007 Cable JJ0007 Cable Items supplied with AD2078 keyboard Items supplied with A...

Page 25: ...150 2350 C 6 Items supplied with AD2078 keyboard Items supplied with AD2150 2350 system JJ0007 Cable HP0082 TERMINAL BLOCK Jumper wires 1 5 4 6 3 2 7 8 5 4 6 3 2 7 1 8 J1 J2 XMIT GND RCD MONITORS RS23...

Page 26: ...L BLOCK 1 2 3 4 5 6 7 8 JJ0007 Cable Items supplied with AD2078 keyboard Items supplied with AD2150 2350 system JJ0007 Cable HP0082 TERMINAL BLOCK 3 wire shielded Belden 8770 or equivalent XMIT GND RC...

Page 27: ...1 8 J1 J2 HP0082 AD2078 5 4 6 3 2 7 1 8 J1 J2 HP0082 AD2078 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 JJ0007 3 wire shielded Belden 8770 or equivalent JJ0007 AD1981 HP0047...

Page 28: ...TYPICAL SYSTEM CONNECTIONS Built in Test Connection Self Test Jumper Connection C 9 AD2078 5 4 6 3 2 7 1 8 J1 J2 Keyboard JJ0007 Cable HP0082 TERMINAL BLOCK XMIT RCD Wall Transformer...

Page 29: ...INDEX...

Page 30: ......

Page 31: ...yout 4 Operation 5 Lens Controls Keyboard Layout 4 Operation 7 Matrix Switching System Connections 2 Menu Programming Control 7 MONITOR Section Buttons Keyboard Layout 4 Operation see also OPERATION M...

Page 32: ......

Page 33: ...functions Keyboard LEDs not visible Verify LEDs brightness level page 3 Initiate built in test to verify LED operation page A 2 No sound from keyboard speaker Verify speaker volume level page 3 Check...

Page 34: ......

Page 35: ...Declares that the product s listed below Name Type System Keyboards Model Number ADS2078X ADS2078RX The system keyboard is provided with external power supply Model TP8193 comply with the EMC Standard...

Page 36: ...Support Center 1 800 442 2225 FAX 914 624 7685 OP2078F Printed in U S A November 1996 SPECIFICATIONS DesktopModels Input AD2078 9 VAC 50 60 Hz 5 W ADS2078X 8 VAC 50 60 Hz 600 mA Size 5 25 W x 16 5 L...

Reviews: