44
American Dryer Corp.
113226 - 11
INSTALLATION
1. Requirements
The F.S.S.
must be
supplied with a minimum water pipe size of 1/2” and be provided with 40 psi +/- 20 psi
(2.75 bar +/- 1.37 bar) of pressure. For use of optional manual bypass, a second source with the same
piping and pressure requirements is required.
Flexible 1/2 feeds
must be
provided to avoid damage to electric water solenoid valve by vibration.
IMPORTANT:
Flexible supply line/coupling
must be
used. Solenoid valve failure due to hard
plumbing connections WILL VOID WARRANTY.
If the rear area of the dryer, or the water supply is located in an area where it will be exposed to cold/
freezing temperatures, provisions
must be
made to protect these water lines from freezing.
WARNING:
If the water in the supply line or water solenoid valve freezes, the F.S.S.
will be
INOPERATIVE!!
IMPORTANT:
Appliance is to be connected to the water mains using a new hose set and the old
hose set
should not be
reused.
2. Water Connections:
The water connection is made to the 3/4”-11.5 NH
hose adaptor, located at the rear upper midsection
of the dryer (refer to the photo).
NOTE:
The 3/4”-11.5 NH is a standard hose
coupling screw thread. It
is
not
to be
confused with 3/4” N.P.T. The sealing of
an NH connection is made with a washer
opposed to the mating threads of an
N.P.T. assembly. The two (2) thread
designs
are
not
compatible.
IMPORTANT:
Flexible supply line/coupling
must be
used. Solenoid valve failure due to hard
plumbing connections WILL VOID WARRANTY.
It is recommended
that a filter
or strainer be installed in the water supply line.