10
Dryers may be positioned side wall to side wall. However, a 1/16" minimum allowance
must be
made for
opening and closing of the control door and the lint door. It is suggested that the dryer be positioned about two (2)
feet away from the nearest obstruction for ease of installation, maintenance, and service (to be measured from
the back guard.) (Refer to the
illustration
on
page 11
for details.)
NOTE
: Air considerations are important for proper and efficient operation.
C. DRYER ENCLOSURE REQUIREMENTS
Bulkheads and partitions
should be
made of noncombustible materials and
must be
located a minimum of 12-
inches (18-inches or more is recommended for ease of installation, maintenance, and service) above the dryer
outer top, except along the front of the dryer which may be partially closed in if desired. The clearance between
the bulkhead header and the dryer
must be
a minimum of 4-inches and
must not
extend more than 4-inches to
the rear of the front. The bulkhead facing
must not
be closed in all the way to the top of the dryer. A 1-inch
clearance is required.
NOTE
: Allowances
must be
made for opening the control door.