background image

sound activation or in this case pan/tilt inversion.

Each dip switch has a preset value. A specific DMX address is set by 
combining the dip switches that sum your desired value. For exam-
ple:  To achieve a DMX address of 21, combine dip switches 1, 3, and 
5. Sense dip switch 1 has a value of 1, dip switch 3 has a value of 4, 
and dip switch 5 has a value of 16, the combination of the create a 
DMX value of 21.

Set DMX address 21:         

Set DMX address 201:

Dip-switches #   1 = 1            

 

Dip-switches #   1 = 1

 

 

3 = 4 

 

 

 

             4 = 8

 

 

5 = 16   

             

             7 = 64

 

 

   = 21   

             

       

8 = 128

   

 

      

 

 

 

 

   =  201

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 
Operation):

 

The  RollerTron™  can  be  controlled  via  DMX-512  proto-

col. The RollerTron™ is a five channel DMX unit. The DMX address is 
set on the bottom panel of the RollerTron.™ Your unit and your DMX 
controller require a standard 3-pin XLR connector 
for data input and data output (Figure 1). If you are 
making your own cables, be sure to use standard 
two conductor shielded cable (This cable may be 
purchased  at  almost  all  pro  sound  and  lighting 
stores). Your cables should be made with a male 
and  female  XLR  connector  on  either  end  of  the 
cable.  Also  remember  that  DMX  cable  must  be 
daisy chained and can not be split.

Figure 1

©

American DJ

®

  -  www.americandj.com  - RollerTron™ Instruction Manual Page 10

©

American DJ

®

  -  www.americandj.com  - RollerTron™ Instruction Manual Page 9

Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

RollerTron.™ The American DJ

®

 RollerTron

 is available in a 120v and 

220v  version.  Because  line  voltage  may  vary  from  venue  to  venue, 
you should be sure your unit voltages matches the wall outlet voltage 
before attempting to operate you fixture.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 
and controllers. 

A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a sin-
gle controller, as long as all fixtures and the controller are DMX com-
pliant.

 To ensure proper DMX data transmission, when using several 

DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

Dip-switches in DMX mode:

 This unit uses dip switches to assign a 

DMX address. Each dip switch represents a binary value. 
Dip Switch 1 address equals 1 

 

Dip Switch 2 address equals 2 

 

Dip Switch 3 address equals 4 

 

Dip Switch 4 address equals 8 
Dip Switch 5 address equals 16 

 

Dip Switch 6 address equals 32
Dip Switch 7 address equals 64 

 

Dip Switch 8 address equals 128
Dip Switch 9 address equals 256

Dip  Switch  10  -  Some  unit  omit  dip  switch  10,  when  a  unit  does 
included dip switch 10 it is usually used for special functions such as 

 RollerTron™ 

 

 

 

 

     

Set Up

 RollerTron™ 

 

 

 

 

     

Set Up

ON

1

9

8

7

6

5

4

3

2

10

128

2

8     32  

256

65

16

4

1

SF

DMX CHANNEL

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Summary of Contents for RollerTron

Page 1: ...that are compatible with the ScanTron and is best used in multiples of four When used as a stand alone unit or when used in multiples linked in a master slave configuration the optional IRC 1 controll...

Page 2: ...r broken Do not attempt to remove or break off the ground prong from the electrical cord This prong is used to reduce the risk of electrical shock and fire in case of an internal short Disconnect from...

Page 3: ...your manufactures war ranty 6 XLR Output Jack This jack is used to transmit the incoming DMX signal to another DMX fixture or transmit a Master Slave signal to the nest RollerTron in the chain For be...

Page 4: ...n the last fixture RollerTron Operation American DJ www americandj com RollerTron Instruction Manual Page 8 American DJ www americandj com RollerTron Instruction Manual Page 7 RollerTron Operation 7 F...

Page 5: ...a that trav els from fixture to fixture via the DATA IN and DATA OUT XLR ter minals located on all DMX fixtures most controllers only have a DATA OUT terminal DMX Linking DMX is a language allowing al...

Page 6: ...breaker button in until you hear it pop back in to place If the breaker continues to pop stop using the unit and contact our customer support team the unit may need to be returned for service RollerTr...

Page 7: ...Low frequencies bass should cause the unit to react to sound Tapping on the microphone quiet or high pitched sounds may not activate the unit 2 Be sure the SENSITIVITY KNOB 5 is not set to the minimum...

Page 8: ...3 582 2610 Web www americandj com E mail info americandj com Model RollerTron Voltage 120v 60Hz or 220v 50Hz Lamp LL ELC 24v 250w Dimensions 21 1 H x 7 87 W x 6 1 D 536mm x 200mm x 155mm Colors 11 Plu...

Reviews: