background image

American DJ

®

  -  www.americandj.com  - Revo XPress Instruction Manual Page 6

American DJ

®

  -  www.americandj.com  - Revo XPress Instruction Manual Page 5

Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

Revo  XPress.  The  American  DJ

®

  Revo  XPress  contains  a  electronic 

ballast, which will auto sense the voltage when it is plugged into the 
power  source.  With  the  electronic  ballast  you  do  not  need  to  worry 
about wall voltage, this unit can be plugged in anywhere.  Also be sure 
to only use the included I.E.C. power cable supplied with the unit.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 
communication  between  intelligent  fixtures  and  controllers. 

A  DMX 

controller sends DMX data instructions from the controller to the fix

-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX  Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of  different  manufactures  to  be  linked  together  and  operate  from  a 

single  controller,  as  long  as  all  fixtures  and  the  controller  are  DMX 

compliant.

  To  ensure  proper  DMX  data  transmission,  when  using 

several DMX fixtures try to use the shortest cable path possible. The 
order in which fixtures are connected in a DMX line does not influence 
the DMX addressing. For example; a fixture assigned a DMX address 
of 1 may be placed anywhere in a DMX line, at the beginning, at the 
end, or anywhere in the middle. Therefore, the first fixture controlled 
by the controller could be the last fixture in the chain. When a fixture 
is  assigned  a  DMX  address  of  1,  the  DMX  controller  knows  to  send 
DATA assigned to address 1 to that unit, no matter where it is located 
in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX 

and  Master/Slave  Operation): 

The  Revo  XPress 

can be controlled via DMX-512 protocol. The Revo 

XPress can be a 4 or 256 channel DMX unit. The 
DMX  address  is  set  electronically  using  the  con-
trols  on  the  rear  panel  of  the  unit.  Your  unit  and 

your DMX controller require a approved DMX-512 
110 Ohm Data cable for data input and data output 
(Figure 1). We recommend Accu-Cable DMX cables. 
If you are making your own cables, be sure to use standard 110-120 

 Revo XPress 

 

                                           Set Up

Figure 1

Ohm shielded cable (This cable may be purchased at almost all pro-
fessional sound and lighting stores). Your cables should be made with 
a  male  and  female  XLR  connector  on  either  end  of  the  cable.  Also 
remember that DMX cable must be daisy chained and cannot be split.

 Revo XPress 

 

 

 

                       Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con

-

nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Summary of Contents for Revo XPress

Page 1: ...lligent LED fixture The fixture has three different operating modes sound active show mode DMX controlled The Revo XPress has twelve shows to choose from The unit can be used as a stand alone unit or...

Page 2: ...len or liquid has been spilled into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance Revo...

Page 3: ...ng the con trols on the rear panel of the unit Your unit and your DMX controller require a approved DMX 512 110 Ohm Data cable for data input and data output Figure 1 We recommend Accu Cable DMX cable...

Page 4: ...pin XLR DMX line When inserting stan dard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The chart below details a p...

Page 5: ...1 12 Programs 1 12 are preset shows while Sh 0 is random mode Press the UP or DOWN buttons to find your desired show and press ENTER to confirm and to select your the speed of your desired program 3...

Page 6: ...The first unit in the chain master will use the female XLR connector only The last unit in the chain will use the male XLR connector only For longer cable runs we suggest a terminator at the last fix...

Page 7: ...find your desired show and press ENTER 3 Select your desired program speed and press ENTER 4 The optional UC3 Controller not included may be used to con trol different functions including blackout Rev...

Page 8: ...will ensure longevity and crisp output 1 Use normal glass cleaner and a soft cloth to wipe down the out side casing 2 Clean the external optics and mirror with glass cleaner and a soft cloth every 20...

Page 9: ...sole responsibility of American DJ Inc under this warranty shall be limited to the repair of the product or replace ment thereof including parts at the sole discretion of American DJ All products cov...

Page 10: ...le None DMX 4 or 256 DMX Channels Sound Active Yes Working Position Any Safe Secure Position Warranty 3 Year 1095 days American DJ Supply American DJ World Headquarters 6122 S Eastern Ave Los Angeles...

Reviews: