2.  On the Master unit press the MENU button until “

SLND

” is dis-   

 

played, press ENTER. Either “

MAST

”, “

SL 1

” (slave mode normal) or  

 

SL 2

” (slave mode 2 light show) will be displayed. Press the UP or  

 

DOWN buttons to set the fixture to “

MAST

”, and press ENTER.

3.  

On the slave units tap the MENU button until “

SLND

” is displayed, 

 

press ENTER. Set the fixture to either “

SL 1

” or “

SL 2

” and press  

 

ENTER.

4.   The slave units will now follow the Master unit.
5

.  

The optional UC3 Controller (not included) may be used to  

    control different functions including blackout.

 

If you want to

  

   

use the optional remote control, connect the UC3 controller to the 

   

first fixture in the line (master).  

 

Stand By

Blackout the unit

Function

1. Synchronous Strobe
2. Sound Strobe
3. Two light Show Strobe

Select Pattern Select  Chase

Mode

Sound
(LED Off )

Pattern
(Led On)

Chase
(Led

 SlowStrobe

)

 Reflex LED DMX™ 

             Operating Instructions

 Reflex LED DMX™ 

                              UC3 Control

 

  Channel 

     Value 

 

  Function (Left Side)

          

1

             

  0 - 255

        

                        PAN

        2               0 - 255                 PATTERNS & CHASES

        

                                                                               

                 

                        

                         0 - 9                               BLACKOUT
                       10 - 19                             PATTERN 1
                       20 - 29                             PATTERN 2
                       30 - 39                             PATTERN 3
                       40 - 49                             PATTERN 4
                       50 - 59                             PATTERN 5
                       60 - 69                             PATTERN 6
                       70 - 79                             PATTERN 7
                       80 - 89                             PATTERN 8
                       90 - 99                             PATTERN 9
                     100 - 109                          PATTERN 10
                     110 - 119                          PATTERN 11
                     120 - 129                          PATTERN 12
                     130 - 139                          PATTERN 13
                     140 - 149                          PATTERN 14
                     150 - 159                          PATTERN 15
                     160 - 169                             CHASE 1
                     170 - 179                             CHASE 2
                     180 - 189                             CHASE 3
                     190 - 199                             CHASE 4
                     200 - 209                             CHASE 5
                     210 - 219                             CHASE 6
                     220 - 229                             CHASE 7
                     230 - 239                             CHASE 8
                     240 - 249                             CHASE 9
                     250 - 255                            CHASE 10         

       

        

        

3                                                        STROBE

                         0 - 9                               NO STROBE      
                       10 - 255                  STROBE SLOW - FAST

  

 

           

 Reflex LED DMX™ 

                                DMX Traits

With  this  feature  you  can  connect  the  fixtures  to  one  another 

using the IEC input and output sockets. The quantity that can be 

connected is 30 fixtures maximum. After 30 fixtures you will need 
to use a new power outlet. They must be the same fixtures. DO 
NOT mix fixtures.

 Reflex LED DMX™ 

     Power Cord Daisy Chaining

Summary of Contents for Reflex LED DMX

Page 1: ...e has two operating modes sound active and DMX control and can be used as a stand alone fixture or in a master slave configuration To optimize beam intensity use this fixture with a fog machine or oth...

Page 2: ...break off the ground prong from the electrical cord This prong is used to reduce the risk of electrical shock and fire in case of an internal short Disconnect from main power before making any type of...

Page 3: ...dress is set electronically using the controls on the rear panel of the unit Your unit and your DMX controller require a approved DMX 512 110 Ohm Data cable for data input and data output Figure 1 We...

Page 4: ...ER 2 1 will now be displayed and flashing Press the UP or DOWN buttons to find your desired address Press ENTER to set your desired DMX address SLND This will let you set unit as a master or slave in...

Page 5: ...gether and operate without a controller In Master Slave operation one unit will act as the control ling unit and the others will react to the controlling units programs Any unit can act as a Master or...

Page 6: ...3 Two light Show Strobe Select Pattern Select Chase Mode Sound LED Off Pattern Led On Chase Led SlowStrobe Reflex LED DMX Operating Instructions Reflex LED DMX UC3 Control Channel Value Function Left...

Page 7: ...t into a standard 110V wall outlet 2 Be sure the fuse has not blown The fuse is located on the rear panel Unit does not respond to sound 1 Low frequencies bass should cause the unit to react to sound...

Page 8: ...es for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of American DJ Inc under this warranty shall be limited to the repair of the product or...

Reviews: