background image

©

American DJ Supply

®

  -  www.americandj.com  - Reflex LED DMX™ User Manual Page 5

©

American DJ Supply

®

  -  www.americandj.com  - Reflex LED DMX™ User Manual Page 6

Power Supply:

 Before plugging your unit in, be sure the source volt

-

age in your area matches the required voltage for your American DJ

®

 

Reflex LED DMX™. The American DJ

®

 Reflex LED DMX

 is available 

in a 120v and 220v version. Because line voltage may vary from venue 
to venue, you should be sure your unit voltage matches the wall outlet 
voltage before attempting to operate you fixture.  Also be sure to only 
use the included I.E.C. power cable supplied with the unit, this cable 
matches the voltage and current requirements of the unit.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 
communication  between  intelligent  fixtures  and  controllers. 

A  DMX 

controller sends DMX data instructions from the controller to the fix

-

ture. DMX data is sent as serial data that travels from fixture to fixture 
via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 
fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 
controller,  as  long  as  all  fixtures  and  the  controller  are  DMX  compli

-

ant.

  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. Therefore, the first fixture controlled by the 
controller could be the last fixture in the chain. When a fixture is as-
signed a DMX address of 1, the DMX controller knows to send DATA 
assigned to address 1 to that unit, no matter where it is located in the 
DMX chain.

Data Cable (DMX Cable) Requirements (For DMX 

and Master/Slave Operation): 

The X-Move LED™ 

can  be  controlled  via  DMX-512  protocol.  The 
Reflex LED DMX™ is be a six channel DMX unit. 
The  DMX  address  is  set  electronically  using  the 
controls on the rear panel of the unit. Your unit and 
your DMX controller require a approved DMX-512 
110 Ohm Data cable for data input and data output 
(Figure 1). We recommend Accu-Cable DMX cables. If you are making 

Figure 1

your own cables, be sure to use standard 110-120 Ohm shielded cable 
(This  cable  may  be  purchased  at  almost  all  professional  sound  and 
lighting stores). Your cables should be made with a male and female 
XLR connector on either end of the cable. Also remember that DMX 
cable must be daisy chained and cannot be split.

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con

-

nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con

-

nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T) will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

  Reflex LED DMX™                                          Set Up

  Reflex LED DMX™                                          Set Up

Summary of Contents for Reflex LED DMX

Page 1: ...e has two operating modes sound active and DMX control and can be used as a stand alone fixture or in a master slave configuration To optimize beam intensity use this fixture with a fog machine or oth...

Page 2: ...break off the ground prong from the electrical cord This prong is used to reduce the risk of electrical shock and fire in case of an internal short Disconnect from main power before making any type of...

Page 3: ...dress is set electronically using the controls on the rear panel of the unit Your unit and your DMX controller require a approved DMX 512 110 Ohm Data cable for data input and data output Figure 1 We...

Page 4: ...ER 2 1 will now be displayed and flashing Press the UP or DOWN buttons to find your desired address Press ENTER to set your desired DMX address SLND This will let you set unit as a master or slave in...

Page 5: ...gether and operate without a controller In Master Slave operation one unit will act as the control ling unit and the others will react to the controlling units programs Any unit can act as a Master or...

Page 6: ...3 Two light Show Strobe Select Pattern Select Chase Mode Sound LED Off Pattern Led On Chase Led SlowStrobe Reflex LED DMX Operating Instructions Reflex LED DMX UC3 Control Channel Value Function Left...

Page 7: ...t into a standard 110V wall outlet 2 Be sure the fuse has not blown The fuse is located on the rear panel Unit does not respond to sound 1 Low frequencies bass should cause the unit to react to sound...

Page 8: ...es for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of American DJ Inc under this warranty shall be limited to the repair of the product or...