background image

Each dip switch has a preset value. A specific DMX address is set by 
combining the dip switches that sum your desired value. For example: 
To achieve a DMX address of 21, combine dip switches 1, 3, and 5. 
Sense dip switch 1 has a value of 1, dip switch 3 has a value of 4, and 
dip switch 5 has a value of 16, the combination of the create a DMX 
value of 21.

Set DMX address 21:         

Set DMX address 201:

Dip-switches #   1 = 1            

 

Dip-switches #   1 = 1

 

 

3 = 4 

 

 

 

             4 = 8

 

 

5 = 16   

             

             7 = 64

 

 

   = 21   

             

       

8 = 128

   

 

      

 

 

 

 

   =  201

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The LED Trispot can be controlled via DMX-512 protocol. The LED Tri-
spot can be either a three or five channel DMX unit. The DMX address 
is  set  on  the  back  panel  of  the  LED  Trispot.  Your  unit  and  your  DMX 
controller require a standard 3-pin XLR connector 
for data input and data output (Figure 1). If you are 
making your own cables, be sure to use standard 
two conductor shielded cable (This cable may be 
purchased  at  almost  all  pro  sound  and  lighting 
stores). Your cables should be made with a male 
and  female  XLR  connector  on  either  end  of  the 
cable.  Also  remember  that  DMX  cable  must  be 
daisy chained and can not be split.

P

ower Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

LED  Trispot.  The  American  DJ

®

  LED  Trispot  is    a  100v  ~  220v  unit. 

Because of voltage setup of the unit you do not have to worry about 
wall output voltage. This unit is compatiable with all wall outputs.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 
and controllers. A DMX controller sends DMX data instructions from 
the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 
controller,  as  long  as  all  fixtures  and  the  controller  are  DMX  compli-
ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 
DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

Dip-switches in DMX mode:

 This unit uses dip switches to assign a 

DMX address. Each dip switch represents a binary value. 
Dip Switch 1 address equals 1 

 

Dip Switch 2 address equals 2 

 

Dip Switch 3 address equals 4 

 

Dip Switch 4 address equals 8 
Dip Switch 5 address equals 16 

 

Dip Switch 6 address equals 32
Dip Switch 7 address equals 64 

 

Dip Switch 8 address equals 128
Dip Switch 9 address equals 256

Dipswitch  10  -  Some  units  omit  dipswitch  10.  When  a  unit  does  in-
clude  dipswitch  10  it  is  usually  used  for  special  functions  such  as 
sound activation.

©American DJ®  -  www.americandj.com  - LED Trispot Instruction Manual Page 5

  LED Trispot                                                              Set Up

©

American DJ Supply

®

  -  www.americandj.com  - LED Trispot Instruction Manual Page 6

Figure 1

  LED Trispot                                                              Set Up

ON

1

9

8

7

6

5

4

3

2

10

128

2

8     32  

256

65

16

4

1

SF

DMX CHANNEL

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Summary of Contents for LED Trispot

Page 1: ...s The LED Trispot is a simple DMX intelligent LED effect This fixture is light weight and compact which makes it a great piece for mobile DJ s and clubs This unit can be used as a stand alone or a sou...

Page 2: ...rds should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to the point they exit from the unit Cleaning The fixture s...

Page 3: ...models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compli ant To ensure proper DMX data transmission when u...

Page 4: ...nit 1 On the Master unit set dipswitch 10 to the On postion 2 On the Slave units set any dipswitches to the On postion American DJ Supply www americandj com LED Trispot Instruction Manual Page 8 Ameri...

Page 5: ...units will follow the Master unit DMX Mode This unit can be a three channel or five channel DMX unit Operating through a DMX controller gives the user the freedom to create their own programs tailore...

Page 6: ...tten authorization was issued to purchaser by American DJ Inc if the product is damaged because not properly maintained as set forth in the instruction manual D This is not a service contract and this...

Page 7: ...American DJ Supply www americandj com LED Trispot Instruction Manual Page 13 LED Trispot Notes American DJ Supply www americandj com LED Trispot Instruction Manual Page 14 LED Trispot Notes...

Page 8: ...ls 3 5 DMX Channels Colors RGB Color Mixing Warranty 3 Year 1095 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior wri...