background image

P

ower Supply:

 The American DJ Jelly Par Profile contains a automatic 

voltage switch, which will auto sense the voltage when it is plugged 

into the power source. With this switch there is no need to worry about 

the correct power voltage, this unit can be plugged in anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Jelly Par Profile can be controlled via DMX-512 protocol. The Jelly 

Par Profile has 7 DMX channel modes, please see page 9 for the differ-

ent modes. The DMX address is set on the back panel of the Jelly Par 

Profile. Your unit and your DMX controller require 

a  standard  3-pin  XLR  connector  for  data  input 

and data output (Figure 1). We recommend Accu-

Cable DMX cables. If you are making your own 

cables,  be  sure  to  use  standard  110-120  Ohm 

shielded cable (This cable may be purchased at 

almost all pro lighting stores). Your cables should 

be made with a male and female XLR connector 

on either end of the cable. Also remember that 

DMX cable must be daisy chained and cannot be 

split.

©

American DJ

®

  -  www.Americandj.com  - Jelly Par Profile User Manual Page 5

  Jelly Par Profile                                                       Set Up

©

American DJ

®

  -  www.Americandj.com  - Jelly Par Profile User Manual Page 6

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

 Jelly Par Profile   

                                           Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer runs  of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Summary of Contents for Jelly Par Profile

Page 1: ...ration This wash has five operating modes Sound Active mode Auto mode RGB mode Static Color mode and DMX control mode To optimize the performance of this product please read these operating instruc tions carefully to familiarize yourself with the basic operations of this unit These instructions contain important safety information regarding the use and maintenance of this unit Please keep this man...

Page 2: ... for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances inclu ding amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the appliance C The appliance has been expo...

Page 3: ...r Manual Page 5 Jelly Par Profile Set Up American DJ www Americandj com Jelly Par Profile User Manual Page 6 Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector Do not con nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield...

Page 4: ...1 8 currently dis played 2 The fixture will now change via sound 3 Press the SET UP button to adjust the sound sensitivity SJ X should be displayed Use the UP or DOWN buttons to adjust the sensitivity SJ 1 is the lowest sensitivity SJ 8 is the highest Static Color Mode 1 Plug the fixture in and press the MODE button until CL X is dis played 2 There are 7 colors to choose from Select your desired c...

Page 5: ...s the 6 Channel DMX Mode To run the 7 Channel Mode press the MODE button until Ch 07 is displayed This is the 7 Channel DMX Mode 4 Please see pages 13 16 for DMX values and traits 5 After you have chosen your desired DMX Channel mode plug in the fixture via the XLR connections to any standard DMX controller Jelly Par Profile Operating Instructions Default Running Mode This is a default running mod...

Page 6: ...ss Example Set DMX Address 1 Press S 0 0 1 Set DMX Address 245 Press S 2 4 5 R G B Press either one of these buttons and the press the or to adjust the brightness and Use these buttons to adjust the flash rate speed of the Auto Run sound sensitivity and program selection DMX Control Operating through an DMX controller gives the user the freedom to create their own programs tailored to their own in...

Page 7: ...100 4 MASTER DIMMER 1 255 0 100 Jelly Par Profile 1 Channel DMX Values Functions Channel Value Function 1 COLOR MACROS 1 7 BASTARD AMBER 8 15 MEDIUM AMBER 16 23 PALE AMBER GOLD 24 31 GALLO GOLD 32 39 GOLDEN AMBER 40 47 LIGHT RED 48 55 MEDIUM RED 56 63 MEDIUM PINK 64 71 BROADWAY PINK 72 79 FOLLIES PINK 80 87 LIGHT LAVENDER 88 95 SPECIAL LAVENDER 96 103 LAVENDER 104 111 INDIGO 112 119 HEMSLEY BLUE 1...

Page 8: ...r Profile 7 Channel DMX Values Functions Channels 1 2 and 3 will not work when Channel 4 is being used When using Channel 6 values 128 239 Channel 5 will control the speed of the programs When using Channel 6 values 240 255 Channel 5 will control the sound sensitivity Channels 1 2 and 3 will not work when Channel 4 is being used Channel Value Function 1 RED 1 255 0 100 2 GREEN 1 255 0 100 3 BLUE 1...

Page 9: ...ries are shipped with the product American DJ Inc shall have no liability whatsoever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or removed if the product is modified in any manner which American DJ Inc concludes after inspection affects the reliability of the product if the product has been repaired or...

Page 10: ... 3 Year 1 095 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice American DJ Supply American DJ World Headquarters 6122 S Eastern Ave Los Angeles CA 90040 USA Tel 323 582 2650 Fax 323 725 6100 Web www americandj com E mail info americandj com American DJ Europe Junostraat 2 6468 EW Kerkrade Netherlands ...