  FREQ 16 Strobe                                      18 Channel Mode

  

Channel      Value 

 

           Function

     1 - 16 

                                                DIMMER

                             0 - 255                              0% - 100% 

        17 

                                        MASTER DIMMER

                             0 - 255                              0% - 100%

        18                                                         STROBING

                             0 - 8                              NO FUNCTION

                             9 - 131                 STROBING SLOW - FAST

                         132 - 139                          NO FUNCTION

                         140 - 181              SLOW OPEN - FAST CLOSE

                         182 - 189                          NO FUNCTION

                         190 - 231              FAST OPEN - SLOW CLOSE

                         232 - 239                          NO FUNCTION

                         240 - 247               SOUND ACTIVE STROBING

                         248 - 255                          NO FUNCTION

  FREQ 16 Strobe                                                    Cleaning

Due to fog residue, smoke, and dust cleaning the internal and exter-

nal optical lenses must be carried out periodically to optimize light 

output.  
1.   Use a soft cloth to wipe down the outside casing.
Cleaning frequency depends on the environment in which the fixture 

operates (i.e. smoke, fog residue, dust, dew). 

Listed below are a few common problems the user may encounter, 

with solutions.
Unit not responding to DMX:
1.  Check that the DMX cables are connected properly and are    

  wired correctly (pin 3 is “hot”; on some other DMX devices    

  pin 2 may be ‘hot’). Also, check that all cables are connected   

  to the right connectors; it does matter which way the inputs    

  and outputs are connected.
Unit does not respond to sound:
1.  Quiet or high pitched sounds will not activate the unit.
If problems are not resolved; Contact American DJ® for service.

 1-800-322-6337

  FREQ 16 Strobe                                       Trouble Shooting

  FREQ 16 Strobe                                     Fuse Replacement

With  this  feature  you  can  connect  the  fixtures  to  one  another 

using the IEC input and output sockets. The quantity that can be 

connected is 3 fixtures maximum. After 3 fixtures you will need to 

use a new power outlet. They must be the same fixtures. DO NOT 

mix fixtures.

  FREQ 16 Strobe                            Power Cord Daisy Chain

Locate and remove the unit’s power cord. Once the cord has been 

removed located the fuse holder located inside the power socket. 

Insert a flat-head screw driver into the power socket and gently pry out 

the fuse holder. Remove the bad fuse and replace with a new one. The 

fuse holder has a built-in socket for a spare fuse be sure not to confuse 

the spare fuse with active fuse.

  FREQ 16 Strobe                                     Photometric Chart

Summary of Contents for FREQ 16 Strobe

Page 1: ...The unit has 4 operating modes Sound Active with adjustable sound sensitivity Show Mode Manual Mode or DMX Control This unit can be used as a stand alone fixture or in a Master Slave configuration Thi...

Page 2: ...e fallen or liquid has been spilled into the appliance C The appliance has been exposed to rain or water D The appliance does not appear to operate normally or exhibits a marked change in performance...

Page 3: ...able must be daisy chained and cannot be split FREQ 16 Strobe Set Up Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector...

Page 4: ...he MENU button for at least 3 seconds CHND This will let select your desired DMX channel mode 1 Press the either the MENU button until CHND is displayed press ENTER Either 1CH 2CH 16CH or 18CH will be...

Page 5: ...what setting you would like to adjust first press the ENTER button Use the UP and DOWN buttons to make adjustments Once you have made your desired adjustments press ENTER 4 Once you have finished wit...

Page 6: ...firm and exit TEST This function will run a self test program 1 Press the MENU button until TEST is displayed press ENTER 2 The fixture will now run a self test Press the MENU button to exit TEMP With...

Page 7: ...is displayed and press ENTER and then press and hold the MENU button to confirm 3 To adjust the sound sensitivity press the MENU button until SENS is displayed Use the UP or DOWN buttons to adjust sen...

Page 8: ...ENTER Use the UP or DOWN buttons to find the MAST setting and press ENTER 3 On the slave units tap the MENU button until SLND is display ed and Press ENTER Use the UP or DOWN buttons to switch between...

Page 9: ...ed properly and are wired correctly pin 3 is hot on some other DMX devices pin 2 may be hot Also check that all cables are connected to the right connectors it does matter which way the inputs and out...

Page 10: ...he product has been repaired or serviced by anyone other than the American DJ Inc factory unless prior written authorization was issued to purchaser by American DJ Inc if the product is damaged becaus...

Reviews: