background image

©American DJ®  -  www.americandj.com  - FREQ 16 Strobe Instruction Manual Page 5

©

American DJ Supply

®

  -  www.americandj.com  - FREQ 16 Strobe Instruction Manual Page 6

P

ower Supply:

 The American DJ

®

 FREQ 16 Strobe contains a auto-

matic voltage switch, which will auto sense the voltage when it is 

plugged into the power source. With this switch there is no need to 

worry about the correct power voltage, this unit can be plugged in 

anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To ensure proper DMX data transmission, when using several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The FREQ 16 Strobe has 4 DMX Channel modes. The DMX address is 

set on the rear panel of the FREQ 16 Strobe. Your unit and your DMX 

controller require a approved DMX-512 110 Ohm Data cable for data 

input and data output. We recommend Accu-Cable DMX cables. If you 

are making your own cables, be sure to use stan-

dard 110-120 Ohm shielded cable (This cable may 

be purchased at almost all professional sound 

and lighting stores). Your cables should be made 

with a male and female XLR connector on either 

end of the cable. Also remember that DMX cable 

must be daisy chained and cannot be split.

  FREQ 16 Strobe                                                        Set Up

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

  FREQ 16 Strobe                                                        Set Up

Summary of Contents for FREQ 16 Strobe

Page 1: ...The unit has 4 operating modes Sound Active with adjustable sound sensitivity Show Mode Manual Mode or DMX Control This unit can be used as a stand alone fixture or in a Master Slave configuration Thi...

Page 2: ...e fallen or liquid has been spilled into the appliance C The appliance has been exposed to rain or water D The appliance does not appear to operate normally or exhibits a marked change in performance...

Page 3: ...able must be daisy chained and cannot be split FREQ 16 Strobe Set Up Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector...

Page 4: ...he MENU button for at least 3 seconds CHND This will let select your desired DMX channel mode 1 Press the either the MENU button until CHND is displayed press ENTER Either 1CH 2CH 16CH or 18CH will be...

Page 5: ...what setting you would like to adjust first press the ENTER button Use the UP and DOWN buttons to make adjustments Once you have made your desired adjustments press ENTER 4 Once you have finished wit...

Page 6: ...firm and exit TEST This function will run a self test program 1 Press the MENU button until TEST is displayed press ENTER 2 The fixture will now run a self test Press the MENU button to exit TEMP With...

Page 7: ...is displayed and press ENTER and then press and hold the MENU button to confirm 3 To adjust the sound sensitivity press the MENU button until SENS is displayed Use the UP or DOWN buttons to adjust sen...

Page 8: ...ENTER Use the UP or DOWN buttons to find the MAST setting and press ENTER 3 On the slave units tap the MENU button until SLND is display ed and Press ENTER Use the UP or DOWN buttons to switch between...

Page 9: ...ed properly and are wired correctly pin 3 is hot on some other DMX devices pin 2 may be hot Also check that all cables are connected to the right connectors it does matter which way the inputs and out...

Page 10: ...he product has been repaired or serviced by anyone other than the American DJ Inc factory unless prior written authorization was issued to purchaser by American DJ Inc if the product is damaged becaus...

Reviews: