Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your ADJ Fog Fury 

3000 WiFly. The ADJ Fog Fury 3000 WiFly is available in a 120v and 

230v version. Because line voltage may vary from venue to venue, you 

should be sure your unit voltage matches the wall outlet voltage before 

attempting to operate you fixture.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Fog Fury 3000 WiFly can be controlled via DMX-512 protocol. The 

Fog Fury 3000 WiFly has 3 DMX channels. The DMX address is set on 

the back panel. Your unit and your DMX controller require a standard 

3-pin XLR connector for data input and data output 

(Figure 1). We recommend Accu-Cable DMX cables. 

If you are making your own cables, be sure to use 

standard 110-120 Ohm shielded cable (This cable 

may be purchased at almost all pro lighting stores). 

Your cables should be made with a male and female 

XLR  connector  on  either  end  of  the  cable.  Also 

remember that DMX cable must be daisy chained 

and cannot be split.

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer runs  of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

  Fog Fury 3000 WiFly    

                DMX Information

  Fog Fury 3000 WiFly    

                DMX Information

Summary of Contents for Fog Fury 3000 WiFly

Page 1: ...l non ADJ Products LLC brands and product names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabili...

Page 2: ...a marked change in performance Fog Fury 3000 WiFly Safety Precautions ADJ Products LLC www adj com Fog Fury 3000 WiFly Instruction Manual Page 3 Introduction Congratulations you have just purchased o...

Page 3: ...n either end of the cable Also remember that DMX cable must be daisy chained and cannot be split Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the grou...

Page 4: ...used if desired however if you intend to sus pend the unit from truss the bracket must be used 4 Fill the fog fluid reservoir with ADJ brand fog juice Place the feed er tube with the filter deep insid...

Page 5: ...unit will now follow the Master Fog Fury 3000 WiFly Master Slave Set Up A XXX DMX Address Setting XXX represents the dis played DMX address 1 Press the MENU UP or DOWN buttons until A XXX is dis play...

Page 6: ...iFly Transceiver The fixture must be set up first before you apply power to WiFly Transceiver 5 If everything is set up properly and the fixture is receiving a Wireless signal Wireless status indicato...

Page 7: ...low the fluid reservoir you can see the LED color through fluid tank If you experience low fog output pump noise or no fog output at all disconnect and discontinue use immediately Do not attempt to co...

Page 8: ...than the ADJ Products LLC factory unless prior written authorization was issued to purchaser by ADJ Products LLC if the product is damaged because not properly maintained as set forth in the instructi...

Reviews: