background image

P

ower  Supply:

  The  American  DJ

®

  Flash  Panel  16  contains  a  elec-

tronic ballast, which will auto sense the voltage when it is plugged into 
the power source. With the electronic ballast you do not need to worry 
about wall voltage, this unit can be plugged in anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 
and controllers. A DMX controller sends DMX data instructions from 
the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 
DMX Linking: DMX is a language allowing all makes and models of 
different manufactures to be linked together and operate from a single 
controller,  as  long  as  all  fixtures  and  the  controller  are  DMX  compli-
ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 
DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.
Dip-switches in DMX mode: This unit uses dipswitches to assign a 
DMX address. Each dipswitch represents a binary value. 
Dipswitch 1 address equals 1 

 

Dipswitch 2 address equals 2 

 

Dipswitch 3 address equals 4 

 

Dipswitch 4 address equals 8 
Dipswitch 5 address equals 16 

 

Dipswitch 6 address equals 32
Dipswitch 7 address equals 64 

 

Dipswitch 8 address equals 128
Dipswitch 9 address equals 256
Dipswitch 10 - Some units omit dipswitch 10. When a unit does include 
dipswitch 10 it is used for special functions such as sound activation.
Each dipswitch has a preset value. A specific DMX address is set by 
combining the dipswitches that sum your desired value. For example:  

To  achieve  a  DMX  address  of  21,  combine  dipswitches  1,  3,  and  5. 
Sense dipswitch 1 has a value of 1, dipswitch 3 has a value of 4, and 
dipswitch 5 has a value of 16, the combination of the create a DMX 
value of 21.
Set DMX address 21:       

 

Set DMX address 201:

Dipswitch # 1 = 1            

 

Dipswitch # 1 = 1

Dipswitch # 3 = 4 

 

 

Dipswitch # 4 = 8

Dipswitch # 5 = 16 

 

  

Dipswitch # 7 = 64

 

 

= 21   

            Dipswitch # 8 = 128

         

 

 

 

 

 

=  201 

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Flash Panel 16 can be controlled via DMX-512 protocol. The Flash 
Panel 16 is a 48 channel DMX unit. The DMX address is set on the back 
panel of the Flash Panel 16. Your unit and your DMX controller require 
a  approved  DMX-512  110  Ohm  Data  cable  for 
data  input  and  data  output  (Figure  1).  We  rec-
ommend  Accu-Cable  DMX  cables.  If  you  are 
making your own cables, be sure to use standard 
110-120 Ohm shielded cable (This cable may be 
purchased at almost all professional sound and 
lighting stores). Your cables should be made with 
a male and female XLR connector on either end 
of the cable. Also remember that DMX cable must 
be daisy chained and cannot be split.

©American DJ®  -  www.americandj.com  - Flash Panel 16 Instruction Manual Page 5

  Flash Panel 16                                                 DMX Set Up

©

American DJ Supply

®

  -  www.americandj.com  - Flash Panel 16 Instruction Manual Page 6

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

  Flash Panel 16                                                 DMX Set Up

ON

1

9

8

7

6

5

4

3

2

10

128

2

8     32  

256

65

16

4

1

SP

DMX CHANNEL

Summary of Contents for FLASH PANEL 16

Page 1: ...LED Panel This LED panel can be controlled via DMX or via the optional CF card controller Model FP CFC Dynamic effects can be played on it which makes it a great system for DJ s and night clubs This...

Page 2: ...t in safe and stable matter Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to the point the...

Page 3: ...activation Each dipswitch has a preset value A specific DMX address is set by combining the dipswitches that sum your desired value For example To achieve a DMX address of 21 combine dipswitches 1 3...

Page 4: ...ndj com Flash Panel 16 Instruction Manual Page 8 American DJ Supply www americandj com Flash Panel 16 Instruction Manual Page 7 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for...

Page 5: ...e programmed to act as the Master Master Slave Connections and Settings 1 Daisy chain your units via the XLR connector on the rear of the unit Use standard XLR microphone cables to link your units to...

Page 6: ...nectors it does matter which way the inputs and outputs are connected Unit does not respond to sound 1 Quiet or high pitched sounds will not activate the unit 2 Check your dipswitch settings If proble...

Page 7: ...nsibility of Ameri can DJ Inc under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of American DJ All products covered by thi...

Page 8: ...1 LEDs Working Position Any safe working position Voltage 90 240V 60 50Hz Power Draw 6W Max Weight 3lbs 1 4Kgs Dimensions 9 8 L x 9 8 W x 1 85 H 250 L x 250 W x 47 H mm Colors RGB Color Mixing DMX Ch...

Reviews: