background image

©

American DJ

®

 - www.americandjeurope.com - Emerald Scan™ Instruction Manual Page 4

 Emerald Scan™    

 

             Safety Precautions

Safety Issues: 

This unit may “pop” the breaker if the maximum allotted 

load of 2 amps is reached.

•  To reduce the risk of electrical shock or fire, do not expose this unit
     rain or moisture.
•   Do not spill water or other liquids  into or on to your unit.
•   Do not attempt to remove or break off the ground prong from the
    electrical cord. This prong is used to reduce the risk of electrical  
   shock and fire in case of an internal short. Do not attempt to oper-
   ate this unit if the power cord has been frayed or broken.
•   Disconnect from main power before making any type of connection.
•   Do not remove the cover under any conditions. There are no user  
   serviceable parts inside.
•   Always be sure to mount this unit in an area that will allow proper  
   ventilation. Allow about 6” (15cm) between this device and a wall.
•   Do not attempt to operate this unit, if it becomes damaged.
•   This unit is intended for indoor use only, use of this product out-
   doors voids all warranties.
•   During long periods of non-use, disconnect the unit’s main power.
•   Always mount this unit in safe and stable matter.
•   Power cords should be routed so they are not likely to be walked  
   on, pinched by items placed upon or against them.
• Cleaning -The fixture should be cleaned only as recommended by  
   the manufacturer. See page 12 for cleaning details.
•   Heat -The appliance should be situated away from heat sources  
   such as radiators, heat registers, stoves, or other appliances    
   (including amplifiers) that produce heat.
•   The fixture should be serviced by qualified service personnel when:
    A.  The power-supply cord or the plug has been damaged.
    B.   Objects have fallen, or liquid has been spilled into the unit.
    C.  The unit has been exposed to rain or water.
    D.   The unit does not appear to operate normally or exhibits a
            marked change in performance.

DANGER

VISIBLE LASER RADIATION

-AVOID DIRECT EYE EXPOSURE
LASER DIODE

WAVELENGTH : 635~650 nm

Max Output : <4.9mW

Class IIIa Laser Product

!

!

©

American DJ

®

  -  www.americandjeurope.com - Emerald Scan™ Instruction Manual Page 13

CHANNEL 1

255

00

00

00

255

TILT

255

CHANNEL 2

00

255

PICTURE

CHANNEL 3

LASER GLITTER

CHANNEL 4

00

255

EFFECT CHANNEL POSITIONS

EMERALD SCAN 

PAN

255

00

0%%D

135%%D

0%%D

70%%D

Slow

Fast

Fast

00

Laser Off

255

Laser On

00-14

15-29

30-44

45-59

60-74

75-89

90-104

105-119

120-134

135-149

150-164

165-179

180-194

195-209

210-224

225-239

240-254

255

  Emerald Scan™    

 

 

               DMX Traits

Summary of Contents for Emerald Scan

Page 1: ...y Cycle None Ventilation Fan Cooled Warranty 90 Days Voltage is preset at the factory and can not be changed by the user Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice Emerald Scan Specifications American DJ American DJ World Headquarters 4295 Charter Street Los Angeles CA 90058 USA Tel 323 582 2650 Fax 3...

Page 2: ... shipping charges must be pre paid If the requested repairs or service including parts replacement are within the terms of this warranty American DJ will pay return shipping charges only to a designated point within the United States If the entire instrument is sent it must be shipped in its original package No accessories should be shipped with the product If any accessories are shipped with the ...

Page 3: ...n Warranty Registration The Emerald Scan carries a 90 day limited warranty Please fill out the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number If the unit is under warranty you must provide a copy of your proof of purchase invoice Please contact American DJ customer su...

Page 4: ...s mount this unit in safe and stable matter Power cords should be routed so they are not likely to be walked on pinched by items placed upon or against them Cleaning The fixture should be cleaned only as recommended by the manufacturer See page 12 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances including ...

Page 5: ... environment in which the fixture operates I e smoke fog residue dust dew In heavy use we rec ommend cleaning on a monthly basis Periodic cleaning will ensure longevity and crisp beam output Emerald Scan Cleaning Emerald Scan Breaker Reset This unit is equipped with a built in safety breaker This breaker is designed to close the power circuit in the event of an internal short or power surge This w...

Page 6: ... page 8 for a detailed explanation of DMX binary code 2 A M P 1 5 6 4 3 2 Emerald Scan Operation react to the controlling units programs Any unit can act as a Master or as a Slave 1 Using standard XLR microphone cables daisy chain your units together via the XLR connector on the rear of the units Remem ber the Male XLR connector is the input and the Female XLR connector is the output For longer ca...

Page 7: ...9 address equals 256 Dipswitch 10 Some units omit dipswitch 10 When a unit does include dipswitch 10 it is usually used for special functions such as Emerald Scan Set Up American DJ www americandjeurope com Emerald Scan Instruction Manual Page 10 Power Supply This unit is available in 120v and 230v Before plug ging your unit in be sure the source voltage in your area matches the required voltage f...

Page 8: ...www americandjeurope com Emerald Scan Instruction Manual Page 8 sound activation Assigning DMX Address Each dipswitch has a preset value A spe cific DMX address is set by combining the dipswitches that sum your desired value For example To achieve a DMX address of 7 combine dipswitches 1 2 and 3 Since dipswitch 1 has a value of 1 dipswitch 2 has a value of 2 and dipswitch 3 has a value of 4 the co...