background image

©

American DJ

®

  -  www.americandjeurope.com - Emerald Scan™ Instruction Manual Page 9

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special  Note:  Line  Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR socket of the last unit 
in your daisy chain to terminate the line. Using a cable terminator (ADJ 
part number Z-DMX/T) will decrease the possibilities of erratic behav-
ior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin XLR 

connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures 
may be implemented in a 3-pin XLR DMX line. When inserting stan-
dard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be 
used, these adaptors are readily available at most electric stores. The 
chart below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Pin 5 - Do Not Use

Pin 4 - Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

  Emerald Scan™    

 

 

                       Set Up

©

American DJ

®

  -  www.americandjeurope.com - Emerald Scan™ Instruction Manual Page 8

sound activation.

Assigning DMX Address: 

Each dipswitch has a preset value. A spe-

cific DMX address is set by combining the dipswitches that sum your 
desired value. For example: To achieve a DMX address of 7, combine 
dipswitches 1, 2, and 3. Since dipswitch 1 has a value of 1, dipswitch 
2 has a value of 2, and dipswitch 3 has a value of 4, the combination 
of the three create a DMX value of 7. (See example below).

Set DMX address 1:         

Set DMX address 7:

Dip-switches #   1 = 1            

 

Dip-switches #   1 = 1

 

 

 

 

 

 

             2 = 2

 

 

 

 

             

             3 = 4

 

 

 

 

             

       

   = 7

   

 

      

 

 

 

 

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 
Operation): 

The Emerald Scan™ can be controlled via DMX-512 pro-

tocol.  The  Emerald  Scan™  is  a  three  channel  DMX  unit.  The  DMX 
address is set on the side panel of the Emerald Scan.™ Your unit and 
your DMX controller require a standard 3-pin XLR connector for data 
input and data output (Figure 1). If you are making your own cables, 
be sure to use standard two conductor shielded cable (This cable may 
be purchased at almost all pro sound and lighting stores). Your cables 
should be made with a male and female XLR connector on either end 
of the cable. Also remember that DMX cable must be daisy chained 
and can not be split.

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

  Emerald Scan™    

 

 

                       Set Up

Summary of Contents for Emerald Scan

Page 1: ...y Cycle None Ventilation Fan Cooled Warranty 90 Days Voltage is preset at the factory and can not be changed by the user Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice Emerald Scan Specifications American DJ American DJ World Headquarters 4295 Charter Street Los Angeles CA 90058 USA Tel 323 582 2650 Fax 3...

Page 2: ... shipping charges must be pre paid If the requested repairs or service including parts replacement are within the terms of this warranty American DJ will pay return shipping charges only to a designated point within the United States If the entire instrument is sent it must be shipped in its original package No accessories should be shipped with the product If any accessories are shipped with the ...

Page 3: ...n Warranty Registration The Emerald Scan carries a 90 day limited warranty Please fill out the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number If the unit is under warranty you must provide a copy of your proof of purchase invoice Please contact American DJ customer su...

Page 4: ...s mount this unit in safe and stable matter Power cords should be routed so they are not likely to be walked on pinched by items placed upon or against them Cleaning The fixture should be cleaned only as recommended by the manufacturer See page 12 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances including ...

Page 5: ... environment in which the fixture operates I e smoke fog residue dust dew In heavy use we rec ommend cleaning on a monthly basis Periodic cleaning will ensure longevity and crisp beam output Emerald Scan Cleaning Emerald Scan Breaker Reset This unit is equipped with a built in safety breaker This breaker is designed to close the power circuit in the event of an internal short or power surge This w...

Page 6: ... page 8 for a detailed explanation of DMX binary code 2 A M P 1 5 6 4 3 2 Emerald Scan Operation react to the controlling units programs Any unit can act as a Master or as a Slave 1 Using standard XLR microphone cables daisy chain your units together via the XLR connector on the rear of the units Remem ber the Male XLR connector is the input and the Female XLR connector is the output For longer ca...

Page 7: ...9 address equals 256 Dipswitch 10 Some units omit dipswitch 10 When a unit does include dipswitch 10 it is usually used for special functions such as Emerald Scan Set Up American DJ www americandjeurope com Emerald Scan Instruction Manual Page 10 Power Supply This unit is available in 120v and 230v Before plug ging your unit in be sure the source voltage in your area matches the required voltage f...

Page 8: ...www americandjeurope com Emerald Scan Instruction Manual Page 8 sound activation Assigning DMX Address Each dipswitch has a preset value A spe cific DMX address is set by combining the dipswitches that sum your desired value For example To achieve a DMX address of 7 combine dipswitches 1 2 and 3 Since dipswitch 1 has a value of 1 dipswitch 2 has a value of 2 and dipswitch 3 has a value of 4 the co...

Reviews: