background image

©

American DJ

®

  -  www.americandj.com - Emerald Scan II Instruction Manual Page 12

©

American DJ

®

  -  www.americandj.com - Emerald Scan II Instruction Manual Page 11

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special  Note:  Line  Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR socket of the last unit 
in your daisy chain to terminate the line. Using a cable terminator (ADJ 
part number Z-DMX/T) will decrease the possibilities of erratic behav-
ior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin XLR 

connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures 

may be implemented in a 3-pin XLR DMX line. When inserting stan-
dard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be 
used, these adaptors are readily available at most electric stores. The 
chart below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Pin 5 - Do Not Use

Pin 4 - Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

  Emerald Scan II    

 

 

                       Set Up

CAUTION IMPORTANT! When installing this projector, make sure 

that it is mounted in a manner that prevents the audience from 

looking  directly  into  the  beam,  and  the  beam  from  striking  the 

audience.

General Operation:

 

This fixture is designed to operate as a stand 

alone,  sound-active  unit,  or  in  a  Master/Slave  configuration.  It  can 
also operate via DMX controller. The Emerald Scan II is ready to be 
plugged in out of the box. After plugging the power cord into a power 
outlet, flip the power switch to. 

Note: Dipswitch #10 in the “On” position will invert the pan and 
tilt  function.  This  function  is  mainly  used  when  using  two  or 
more fixtures.

  Emerald Scan II    

 

 

                  Operation

Operating Modes:

Universal DMX Control: 

This mode allows you to use a universal 

DMX-512  controller  such  as  the  American  DJ

®

  DMX  Operator™  or 

Show Designer.™ 
1.  To control your fixture in DMX mode, follow the set-up procedures  
 

on pages 9-11 as well as the set-up procedures included with

 

your DMX controller. 

2.  For longer cable runs (more than a 100 feet) use a terminator on  
 

the last fixture.

3.  The Emerald Scan II uses five DMX channels. See page 14 for  
 

detailed description of the DMX traits. Use your DMX controller 

 

 to activate the various built-in patterns. 

4.  For help operating in DMX mode consult the manual included   
 

with your DMX controller.

Stand-Alone  Operation  (Sound  Active):

 

This  mode  allows  a 

single unit to run to the beat of the music. Only use this mode when  
running a single unit, or when running several units as individuals.
1.  Set dipswitch #1 to the “ON” positon to activate Stand-Alone.  
2.  The unit will react to the low frequencies of music via the  

 

      internal microphone. 
3.  The optional

 BC 30 Controller 

(not included)

 

may be used with  

 

this mode to control different functions including blackout.

Master-Slave  Operation  (Sound  Active): 

This  mode  will  allow 

Summary of Contents for Emerald Scan II

Page 1: ...e contact our toll free customer support number for fur ther instructions Please do not return the unit to your dealer without first contacting customer support Customer Support American DJ provides a toll free customer support line to provide set up help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web at www america...

Page 2: ...if it becomes damaged This unit is intended for indoor use only use of this product out doors voids all warranties During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable matter Power cords should be routed so they are not likely to be walked on pinched by items placed upon or against them Cleaning The fixture should be cleaned only as recommended ...

Page 3: ...t eye exposure In the laser safety regulation it is not legal to aim Class 3R lasers in areas which people can get exposed This is true even if it is aimed below people s faces such as on a dance floor Do not operate the laser without first reading and understanding all safety and technical data in this manual Always set up and install all laser effects so that all laser light is at least 3 meters...

Page 4: ...nsmit the incoming DMX signal to another DMX fixture or transmit a Master Slave signal to the next Emerald Scan II in the chain For best results in DMX or Master Slave mode terminate this jack if it is the last unit in the chain See Terminator on page 9 5 BC 30 Controller Jack This jack is for use with the optional BC 30 controller only Do not attempt to connect an audio signal to this jack this w...

Page 5: ...switch 6 address equals 32 Dipswitch 7 address equals 64 Dipswitch 8 address equals 128 Dipswitch 9 address equals 256 Dipswitch 10 Some units omit dipswitch 10 When a unit does include dipswitch 10 it is usually used for special functions such as Emerald Scan II Set Up sound activation Assigning DMX Address Each dipswitch has a preset value A spe cific DMX address is set by combining the dipswitc...

Page 6: ... Compliment signal Ground Shield 3 Pin XLR to 5 Pin XLR Conversion Emerald Scan II Set Up CAUTION IMPORTANT When installing this projector make sure that it is mounted in a manner that prevents the audience from looking directly into the beam and the beam from striking the audience General Operation This fixture is designed to operate as a stand alone sound active unit or in a Master Slave configu...

Page 7: ... blackout Emerald Scan II Fuse Replacement Emerald Scan II DMX Traits Fixture Cleaning Due to fog residue smoke and dust cleaning the internal and external lenses should be carried out periodically to optimize light output 1 Use normal glass cleaner and a soft cloth to wipe down the out side casing 2 Clean the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dr...

Page 8: ...k up During the period specified above American DJ Inc will replace defec tive parts at its expense with new or refurbished parts and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of American DJ Inc under this warranty shall be limited to the repair of the product or replace ment thereof including parts at the...