Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

Dynasty Scan DMX The American DJ

®

 Dynasty Scan DMX is available 

in a 120v and 220v version. Because line voltage may vary from venue 
to venue, you should be sure your unit voltage matches the wall outlet 
voltage before attempting to operate you fixture. 

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 
communication  between  intelligent  fixtures  and  controllers. 

A  DMX 

controller sends DMX data instructions from the controller to the fix-
ture. DMX data is sent as serial data that travels from fixture to fixture 
via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 
fixtures (most controllers only have a DATA “OUT” terminal). 

DMX  Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of  different  manufactures  to  be  linked  together  and  operate  from  a 
single  controller,  as  long  as  all  fixtures  and  the  controller  are  DMX 
compliant.

  To  ensure  proper  DMX  data  transmission,  when  using 

several DMX fixtures try to use the shortest cable path possible. The 
order in which fixtures are connected in a DMX line does not influence 
the DMX addressing. For example; a fixture assigned a DMX address 
of 1 may be placed anywhere in a DMX line, at the beginning, at the 
end, or anywhere in the middle. Therefore, the first fixture controlled 
by the controller could be the last fixture in the chain. When a fixture 
is  assigned  a  DMX  address  of  1,  the  DMX  controller  knows  to  send 
DATA assigned to address 1 to that unit, no matter where it is located 
in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The Dynasty Scan DMX can be controlled via DMX-512 

protocol. The Dynasty Scan DMX is a six channel 
DMX  unit.  The  DMX  address  is  set  electronically 
using the controls on the side panel of the unit. Your 
unit and your DMX controller require a standard 3-
pin XLR connector for data input and data output 
(Figure 1). If you are making your own cables, be 
sure to use standard two conductor shielded cable 
(This cable may be purchased at almost all profes-
sional  sound  and  lighting  stores).  Your  cables  should  be  made  with 

 Dynasty Scan DMX 

 

           

             Set Up

Figure 1

a  male  and  female  XLR  connector  on  either  end  of  the  cable.  Also 
remember that DMX cable must be daisy chained and cannot be split.

 Dynasty Scan DMX 

 

 

 

              Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer  runs of  cable are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Summary of Contents for Dynasty Scan DMX

Page 1: ...or in a Master Slave configuration The Dynasty Scan DMX is best used in multiples of four When used as a stand alone unit or when used in multiples linked in a master slave configuration For best res...

Page 2: ...en A Objects have fallen or liquid has been spilled into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change...

Page 3: ...he side panel of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input and data output Figure 1 If you are making your own cables be sure to use standard two...

Page 4: ...ning Time To view the Lamp Running Time press the LEFT or RIGHT arrow buttons until L TIME is displayed then press either the UP or DOWN buttons to view the running time Press the RIGHT arrow button t...

Page 5: ...select either On or Off Once you have decided press the either the RIGHT or LEFT arrow buttons to exit the submenu RESET To Reset the unit press the LEFT or RIGHT arrow but tons until RESET is displa...

Page 6: ...operating in DMX mode consult the manual included with your DMX controller Stand Alone Operation Sound Active This mode allows a single unit or several units linked together to run to the beat of the...

Page 7: ...low the proper handling procedures that deal with halogen lamps 2 Loosen the small screw located on the front of the unit 3 After loosening the screw remove the socket assembly cover to expose the lam...

Page 8: ...PURPLE 160 175 YELLOW RED 176 191 DARK GREEN ORANGE 192 255 RAINBOW EFFECT SLOW FAST 4 GOBO 0 15 NOTHING 16 31 SPOT 32 47 GOBO 1 48 63 GOBO 2 64 79 GOBO 3 80 95 GOBO 4 96 111 GOBO 5 112 127 GOBO 6 128...

Page 9: ...ted point within the United States If the entire instrument is sent it must be shipped in its original package No accessories should be shipped with the product If any accessories are shipped with the...

Page 10: ...one DMX 6 Channels Sound Active Yes Working Position Any Safe Secure Position Warranty 1 Year 365 days Voltage is preset at the factory and is not user selectable Please Note Speci cations and improve...

Reviews: