Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

DJ Spot 300. The American DJ

®

 DJ Spot 300 is available in a 120v only. 

Because line voltage may vary from venue to venue, you should be 
sure your unit voltage matches the wall outlet voltage before attempt-

ing to operate you fixture.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 
communication  between  intelligent  fixtures  and  controllers. 

A  DMX 

controller sends DMX data instructions from the controller to the fix

-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX  Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of  different  manufactures  to  be  linked  together  and  operate  from  a 

single  controller,  as  long  as  all  fixtures  and  the  controller  are  DMX 

compliant.

  To  ensure  proper  DMX  data  transmission,  when  using 

several DMX fixtures try to use the shortest cable path possible. The 
order in which fixtures are connected in a DMX line does not influence 
the DMX addressing. For example; a fixture assigned a DMX address 
of 1 may be placed anywhere in a DMX line, at the beginning, at the 
end, or anywhere in the middle. Therefore, the first fixture controlled 
by the controller could be the last fixture in the chain. When a fixture 
is  assigned  a  DMX  address  of  1,  the  DMX  controller  knows  to  send 
DATA assigned to address 1 to that unit, no matter where it is located 
in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The DJ Spot 300 can be controlled via DMX-512 protocol. 

The DJ Spot 300 is a eight channel DMX unit. The 
DMX  address  is  set  electronically  using  the  con-
trols  on  the  side  panel  of  the  unit.  Your  unit  and 
your DMX controller require a standard 3-pin XLR 
connector  for  data  input  and  data  output  (Figure 
1). If you are making your own cables, be sure to 
use standard two conductor shielded cable (This 
cable may be purchased at almost all professional 
sound and lighting stores). Your cables should be made with a male 

 DJ Spot 300 

 

 

 

     

             Set Up

Figure 1

and female XLR connector on either end of the cable. Also remember 
that DMX cable must be daisy chained and cannot be split.

 DJ Spot 300 

 

 

 

     

             Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Summary of Contents for DJ Spot 300

Page 1: ...ly to familiarize yourself with the basic operations of this unit These instructions contain important safety information regard ing the use and maintenance of this unit Please keep this manual with t...

Page 2: ...wn Personal Safety Please Read and Understand This Manual Completely Before You Attempt To Install Or Operate This Unit To reduce the risk of electrical shock or fire do not expose this unit rain or m...

Page 3: ...ase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the retur...

Page 4: ...eep the vents clean at all times A blocked or malfunctioning cooling system may shorten lamp life and unit reliability 9 Lamp Assembly and Access Plate This plate accesses the lamp socket assembly The...

Page 5: ...l of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input and data output Figure 1 If you are making your own cables be sure to use standard two conductor s...

Page 6: ...tem menu You can leave any menu setting without making any changes by pressing the ESC ESCAPE button MAIN MENU A 001 DMX Address Setting 1 Press the ESCAPE button until A 001 is displayed Press the EN...

Page 7: ...e display and press ENTER to confirm the new display 3 Press ESC to return to the main menu VERS Use this function to display the Software version of the unit 1 Press the ESCAPE ESC button until A 001...

Page 8: ...ow you to create your own programs 5 Follow the instruction on page 16 to set the DMX address 6 For longer cable runs more than a 100 feet use a terminator on the last fixture 7 For help operating in...

Page 9: ...moving the screws gently slide out the socket assembly from the rear of the unit to expose the lamp 4 Carefully remove the old lamp and discard it in the trash 5 Replace the lamp with an exact match a...

Page 10: ...INK 93 99 PINK 100 106 PINK LIGHT BLUE 107 113 LIGHT BLUE 114 120 LIGHT BLUE LIGHT GREEN 121 127 LIGHT GREEN 128 255 RAINBOW EFFECT SLOW FAST 4 GOBO WHEEL 0 15 SPOT 16 31 GOBO 1 32 47 GOBO 2 48 63 GOB...

Page 11: ...o a designated point within the United States If the entire instrument is sent it must be shipped in its original package No accessories should be shipped with the product If any accessories are shipp...

Page 12: ...ar 365 days Voltage is preset at the factory and is not user selectable Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior w...

Reviews: