background image

Special Note:

For excessive cable runs of 100ft. total or more, we recommend using a termi-

nator of 80-100 ohms/.5w.  Long cable runs can sometimes cause erratic behavior.  Using a cable ter-
minator will decrease the possibilities of erratic behavior.

For best results use fog or special effects smoke to enhance the beams projections.  

The DJ

Scan

comes with a protective transportation cover.  Be sure to remove it before attempt-

ing any operation!

Stand-Alone Operation (

Sound Active

):

1.  To operate as a stand alone unit, via its internal chases and microphone, turn all dip switches off

(see Diagram1).

2. Adjust the sensitivity knob on the bottom of the unit so the unit will react to sound.
3. The DJ Scan™ will now react to the bass sound of music via the internal microphone.

Master-Slave Operation (

Sound Active

):

1.  This function will allow you to link up to 16 units to run on the master units internal programs.
2. In Master-Slave operation one unit will act as the controlling unit and the others will react to the 

controlling units programs.  Any unit can act as a Master or as a Slave.

3. Daisy chain your units via the XLR connector on the bottom of the units.
4. Use standard XLR microphone cables to link your units together.  

Remember that the Male XLR

connector is the input and the Female XLR connector is the output.

5. The first unit in the chain (master) will use the female XLR connector only - The last unit in the chain 

will use the male XLR connector only.

6. Turn all the master units dip switches to the off position (see Page 6/Diagram1).
7. Please follow chart on page 4 for all slave dipswitch settings. 

Note only one fixture may use the 

master units dip switch settings (see Page 4/Diagram1).

8. After all the units settings have been set and are plugged in, adjust the sensitivity knob on the 

bottom of the master unit to make them react to sound.

Note:  

Stand-Alone and Master -Slave operation require sound to activate!

DJ Scan™ Set Up Cont.

XLR MALE SOCKET

1 EARTH

2 COLD

HOT 3

XLR FEMALE SOCKET

1 EARTH

2 COLD

3 HOT

Figure 2

XLR Pin Configuration:

Pin 1 = Shield

Pin 2 = Data Compliment (negative)

Pin 3 = Data True (positive)

DJ Scan™ Operating Instructions

American DJ Supply

®

.  Los Angeles, CA. 90058 USA   DJ Scan  

Page 3

Summary of Contents for DJ SCAN

Page 1: ...at piece for mobile DJ s roller rinks small clubs bars and bowling cen ters When used in multiples of two 2 or more these units create an effect that rivals that of units that can cost up to three tim...

Page 2: ...DC 9v 200mA power supply The DMX Operator is available in a 115v and 230v version Because line voltage may vary from venue to venue you should be sure to plug your power supply into a matching wall ou...

Page 3: ...o the controlling units programs Any unit can act as a Master or as a Slave 3 Daisy chain your units via the XLR connector on the bottom of the units 4 Use standard XLR microphone cables to link your...

Page 4: ...d DMX controller Follow the set up specifications that come with the controller 1 To focus a DJ Scan it is best to first turn down the music sensitivity knob to its minimum position 2 Loosen the thumb...

Page 5: ...lean the internal optics with glass cleaner and a soft cloth every 30 60 days 5 Always be sure to dry all parts completely before plugging the unit in Cleaning frequency depends on the environment in...

Page 6: ...DJ Scan DMX 512 Chart 1 ON 9 8 7 6 5 4 3 2 1 ON 9 8 7 6 5 4 3 2 1 ON 9 8 7 6 5 4 3 2 1 ON 9 8 7 6 5 4 3 2 1 ON 9 8 7 6 5 4 3 2 1 ON 9 8 7 6 5 4 3 2 1 ON 9 8 7 6 5 4 3 2 1 ON 9 8 7 6 5 4 3 2 1 ON 9 8 7...

Page 7: ...bo 7 Gobo 5 Gobo 4 Gobo 3 Gobo 2 Gobo 1 Purple Pink Orange Yellow Green Blue Red White Lamp On 0o 0o 45o 45o 90o 90o Shutter Gobo 11 Gobo 10 Gobo 9 American DJ Supply Los Angeles CA 90058 USA DJ Scan...