background image

American Beauty®Resistance Soldering Systems

Timer Instruction Sheet

Manufacturers of American Beauty® Quality Soldering 

Tools.

Topic:

 

Understanding the Available Functions and Specifications of the Model 105PTM Digital 

LCD Precision Timer Module.

Description:

  This Timer Module is a self contained, digital LCD, multiple functions precision timing control 

device,  that   has  been   specifically   developed  for  use   with   many   of   the   American  Beauty®  Resistance  
Soldering Systems and Power Units that are available.

Although there are several different functions available for use, the “

L

 One Shot Out” function is 

recommended as the most appropriate type of operation for most of the standard Resistance Soldering 

applications that it is intended to be used on.

Functions

: Choosing one of the available functions is achieved by setting the output mode selector to the 

appropriate letter designator as shown on the chart above. Each of the available functions of this unit is 
described   in   detail   below.   The   functions   that   are   shown   as   (

Continuous

)   will   require   maintaining   a 

continuous depression of the footswitch throughout the completion of their respective cycles. The functions 
that are shown as (

Momentary

) require only a momentary depression of the footswitch to initiate their 

respective cycles.

A

 On Delay = Time proceeds when the footswitch is depressed. The output is energized at the completion 

of the preset and remains on as long as footswitch remains depressed. Upon release of the footswitch the 
output is no longer energized and the counter returns to zero. (

Continuous

)

B

 Interval Delay = Time proceeds and the output is energized when the footswitch is depressed. The output 

is energized for the duration of the preset as long as the footswitch remains depressed. Upon release of the  
footswitch the output is no longer energized and the counter returns to zero. (

Continuous

)

C

 Signal Start On Delay = Time proceeds when the footswitch is depressed. The output is energized at the  

completion of the preset and remains on until the power is interrupted or the output mode is changed. 
(

Momentary

)

D

  Flicker   =   Time   proceeds   when   the   footswitch   is   depressed.   The   output   becomes   energized   at   the 

completion of the first preset cycle and remains energized from the beginning until the end of the second  
preset cycle. The output is off during the third cycle, then energized again during the fourth, etc. This OFF-
ON-OFF timed cycling function will repeat as long as the footswitch remains depressed. Upon release of the 
footswitch the output is no longer energized and the counter returns to zero. (

Continuous

)

E

  Signal   Start   Flicker   Interval   =   Time   proceeds   and   the   output   is   energized   when   the   footswitch   is 

depressed. The output is energized for the duration of the first preset cycle. It then turns off and remains off 

1937 Barrett Drive, Troy  MI  48084     Phone: 800-550-2510 Fax: 248-280-2878

www.americanbeautytools.com

Reviews: