background image

American Beauty®Resistance Soldering Systems

Timer Instruction Sheet

Manufacturers of American Beauty® Quality Soldering 

Tools.

for the duration of the second preset cycle. The output is energized during the third cycle and off again 
during the fourth, etc. This ON-OFF-ON timed cycling function will repeat until the power is interrupted or  
the output mode is changed. (

Momentary

)

F

 One Shot Out Flicker = Time proceeds when the footswitch is depressed counting from zero to the preset 

value. The output energizes as one shot (0.3 Seconds) at the end of the preset cycle, then resets to zero 
and begins counting again. The cycle will repeat in this manner until the power is interrupted or the output 
mode is changed. (

Momentary

)

H

  Off Delay = The output is energized when the footswitch is depressed. The time proceeds when the 

footswitch   is  released   and  the  output   is  energized   for   the   duration   of   the  preset.  If  the  footswitch   is 
depressed again during the cycle the output will remain energized and the counter will hold at zero. The 
time proceeds again upon release of the footswitch and the output is energized for the duration of the  
preset. (

Momentary

)

K

 On/Off Delay = Time proceeds and the output is energized when the footswitch is depressed. The output  

is energized for the duration of the preset as long as the footswitch remains depressed. Releasing the 
footswitch will reset the counter to zero and begin the energized cycle again. Each time the footswitch is  
either depressed or released the counter will reset to zero and the energized cycle will begin. (

Continuous

)

L

 One Shot Out = Time proceeds and the output is energized when the footswitch is depressed. The output  

is energized for the duration of the preset. Releasing the footswitch will not interrupt or interfere with the  
active cycle. After the completion of the preset cycle the footswitch can be depressed again to start the  
next cycle. The counter is returned to zero and a new energized cycle begins each time the footswitch is  
depressed. (

Momentary

)

N

 Integration Time = Time proceeds when the footswitch is depressed and held. The output is energized 

after the completion of the preset cycle and remains energized until power is interrupted. Releasing the 
footswitch during the preset cycle will interrupt the counter, which will resume when the footswitch is again  
depressed. Releasing the footswitch after the output is energized will have no effect on the output, which 
remains energized until the power is interrupted.

Specifications

:

Output Device Operating Limits:

American Beauty® Resistance Soldering Power Units @ 0 to 1200watts.

Ambient Operating Temperature:

-10 to 55°C (at non-freezing status).

Ambient Operating Humidity:

35 to 85% Relative Humidity.

Insulation Resistance:

100 M ohms Min @ 500VDC between power input terminal and control 

output terminal.
Dielectric Strength:

2000VAC   50/60Hz   for   1   minute   between   power   input   terminal   and   control 

output terminal.
Noise:

±2KV the square wave noise (pulse width : 1

µs

) by the noise simulator.

Mechanical Service Life:

Minimum rating is 10,000,000 operations.

Electrical Service Life:

Minimum rating is 100,000 operations @ 120VAC 10A (resistive load).

Setup

:   The   Precision   Timer   Module   may   be   plugged   directly   into   a   standard   110-120VAC   three   wire 

grounded 5-15Nema-type outlet.
 The Footswitch should be plugged into the low voltage 3.5mm receptacle that is located on the lower front  
panel of the Timer Module.
 The American Beauty® Resistance Soldering Power Unit that you intend to use should be plugged into the 
5-15 receptacle located on the front of the Timer Module.
 Be sure to verify the output mode selection before you begin operating the timer Module, remember that  
the exact output operation will be determined by the specific output mode that has been selected.

1937 Barrett Drive, Troy  MI  48084     Phone: 800-550-2510 Fax: 248-280-2878