![AMCI SMD17K User Manual Download Page 18](http://html1.mh-extra.com/html/amci/smd17k/smd17k_user-manual_2921174018.webp)
SMD17K S
PECIFICATIONS
SMD17K User Manual
ADVANCED MICRO CONTROLS INC.
18
Status LED’s (continued)
Error LED
The ERR LED location houses a red/green LED. The red LED indicates an error state in the EtherCAT
protocol. The green LED indicates the operational state of the SMD17K itself. Both LEDs can be on
simultaneously.
Table R1.4 Red ERR LED States
Table R1.5 Green ERR LED States
Red LED State
Description
Off
No errors in device operation
Single blink
200 ms ON / 1 s OFF
Problems with synchronization such as with the Distributed
Clock (DC) PLL.
Double Blink
200 ms Pulses / 1 s between
SYNC manager watchdog timeout. The master has not updated
the output data in the configured time interval. The SMD17K
has switched to the Safe-Op state.
Slow Blink
(1 Hz)
All other issues, such as cable disconnect. The SMD17K has
switched to the Safe-Op state.
Green LED State
Description
Solid Green
Device in the EtherCAT Init state
Very Slow Blink Green
‡
(0.5 Hz)
Driver Fault (Overtemperature fault, etc.)
Slow Blink Green
‡
(1 Hz)
Unsuccessful write to flash memory
Fast Blink Green
‡
(4 Hz)
Successful write to flash memory
Summary of Contents for SMD17K
Page 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S292...
Page 6: ...TABLE OF CONTENTS SMD17K User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Page 48: ...CALCULATING MOVE PROFILES SMD17K User Manual ADVANCED MICRO CONTROLS INC 48 Notes...
Page 76: ...COMMAND DATA FORMAT SMD17K User Manual ADVANCED MICRO CONTROLS INC 76 Notes...
Page 94: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...
Page 96: ...DISTRIBUTED CLOCK SYNC0 SETUP SMD17K User Manual ADVANCED MICRO CONTROLS INC 96...
Page 98: ...DISTRIBUTED CLOCK SYNC0 SETUP SMD17K User Manual ADVANCED MICRO CONTROLS INC 98...