background image

 

 
 
 

 

 

 5 

 

AV CONDITIONER 1000 / ©AMC VIBRO Sp. z o.o. 

 

4.1.

 

Installing / replacing batteries 

In order to install or replace the batteries, remove the front panel of the  casing after removing  two 
screws marked with the number 1 on Fig. 4.1, so that container for four AAA cells can be reached (Fig. 
4.2). After putting new AAA cells into the container, insert it into the housing, and mount the front panel 
back on its place with the screws. 

The need to replace the cells is indicated by the ‘Low Batt’ LED. 

WARNING! 

Do not leave discharged batteries in the device, as it may

 

cause a leak, resulting in damaging of 

the conditioner. 

WARNING! 

If the conditioner is not used for a long time, remove the batteries to avoid leakage and damage. 

4.2.

 

Power supply 

The unit can be powered with external power supply with 9V DC output voltage and minimal current 
load of 100 mA. AC adapter is available as an option. It is recommended to use the AC transformer with 
linear stabilization. Using a power supply with pulse stabilization can drastically increase the noise level 
at the output of the conditioner. 

WARNING! 

Pay attention to the polarity of the adapter plug  – it should be in line with the outlet polarity 
marked  on  the  top  of  the  cabinet.  Connecting  the  power  supply  incorrectly  may  damage  the 
conditioner. 

 

Figure 4.1 View of the screws allowing access to 
the battery compartment.

 

Figure 4.2 View of the removed battery container

 

Summary of Contents for AV CONDITIONER 1000

Page 1: ...ITIONER 1000 amc VIBRO Sp z o o Pilotow 2e 31 462 Krakow Poland T 48 12 362 97 60 S 48 12 362 97 63 info amcvibro pl KRS No 0000618618 REGON No 364497010 VAT No 6772403385 www amcvibro pl SINGLE CHANN...

Page 2: ...nts 1 Introduction 3 2 Technical data 3 3 Description of the AVC 1000 4 4 Power supply 4 4 1 Installing replacing batteries 5 4 2 Power supply 5 5 Using the conditioner 6 6 Troubleshooting 6 7 Recycle...

Page 3: ...frequency response very good linearity and low noise Is also equipped with an LED indicating open or short circuit in the sensor loop The device can be powered up either by an adapter or an internal b...

Page 4: ...ates the device 3 Red LED Sensor Error continuous light indicates open or short circuit 4 Red LED Power continuous light indicates operation 5 Red LED Low Batt continuous light indicates the need to r...

Page 5: ...ioner WARNING If the conditioner is not used for a long time remove the batteries to avoid leakage and damage 4 2 Power supply The unit can be powered with external power supply with 9V DC output volt...

Page 6: ...onnected correctly with compatible polarity in case of a regulated power supply make sure that it is set to supply 9V check that the power supply is turned on No signal on conditioner s output Check i...

Page 7: ...rcury cadmium hexavalent chromium polybrominated biphenyls polybrominated diphenyl ether or other battery related materials are limited to no more than trace amounts 7 2 Recycling Facilities When deco...

Reviews: