Technical Information
50
Precision Induction Heating
A
MBRELL
®
Doc#801-9526-00.doc
Comm.
Arg. Result
Example
%amps
#
Sets the amps setpoint to a percentage of amps output. %
must be enabled in the configuration menu to use this
command.
1,%amps,45
? none
Returns a list of commands and abbreviated descriptions of
each command.
1,?
aldelay #.##
Sets the alarm delay value in Seconds (two decimal places
only). This is the delay time after heat is turned on before the
system will check if the actual present power value falls
outside of the minimum or maximum settings. (ADDED V5.02
display firmware)
1,aldelay,10.21
almax #
Sets the alarm maximum value in WATTS. (ADDED V5.02
display firmware)
1,almax,1200
almin #
Sets the alarm minimum value in WATTS. (ADDED V5.02
display firmware)
1,almin,800
aloff none
Turns on the alarm function. If after the programmed delay
time as extinguished if the power falls outside of the minimum
or maximum power levels the alarm symbol will be displayed.
(ADDED V5.02 display firmware)
1,aloff
alon none
Turns on the alarm function. If after the programmed delay
time as extinguished if the power falls outside of the minimum
or maximum power levels the alarm symbol will be displayed.
(ADDED V5.02 display firmware)
1,alon
amps
#.##
Sets the amps setpoint of the power supply if the control from
location is RS485. Variable can be 0 to max amps. See
maxamps command.
1,amps,100
c? none
Returns the CHDR and CTIME settings of the power supply.
See CHDR and CTIME commands for description.
1,c?
cdata none
Continuous reply includes a description header line followed
by a data line. The data line includes Heat status, set point,
amps out, power out, frequency and timer.The header line
may be changed to repeat at different intervals based on
CHDR command. The rate at which the response is sent is
based on the CTIME command. See ctime for description. If
the timer is set on the power supply the timer will count down
during heat on. If the timer is not set then the timer will count
up during heat on.
1,cdata
chdata none
Continuous 2 line response. Same as cdata without a line
feed. Terminal window will not scroll. The rate at which the
response is sent is based on the CTIME command. See ctime
for description.
1,chdata