4
Figure 3.b. Recommended Methods of Heater Suspension.
Where chain supports have an
angle of inclination greater
than 15° an equal and opposite
support is recommended
.
Vertical suspension chain ideal.
Where supports are inclined,
maximum recommended angle
of inclination is 15°.
Shackle method of
attachment. Pin must
be tightened b
y
pliers.
Drop rod w
ith formed hook.
note. hook or e
y
ebolt
must
be closed tight.
15° max.
ON U TUBE VARIANTS THE HEATE
R
SHOULD
SL
OPE DOWNWARDS TOW
ARDS THE RE
TURN BE
ND
AND ON
LINEAR V
ARIANT
S SHOULD SLO
PE DOWNWARDS TOWARDS BURNER
BY APPROX. 10mm FOR BOTH
HORIZONTAL AND WALL MOUNTE
D
INSTALL
A
TIONS.
T
y
pical Spe
edlink attachment.
*
These an
gles to
be equal and not
more than 45°.
Vertical or i
nclined
suspension on this
plane is ac
ceptable.
*
*
U TUBE
SUSPENSION
*
*
**
Alternative suspension
for Linear via single ch
ain.
SINGLE LI
NEAR
SUS
PENSI
ON
**