Ambient Weather WH117L User Manual Download Page 12

 

Version 2.1  

©Copyright 2015,   

 

 

 

Page 12 

thermometer. Bi-metal (dial) and other digital thermometers are not a good source and have their own 
margin of error. Using a local weather station in your area is also a poor source due to changes in 
location, timing (airport weather stations are only updated once per hour) and possible calibration 
errors (many official weather stations are not properly installed and calibrated). 
 
Place the sensor in a shaded, controlled environment next to the fluid thermometer, and allow the 
sensor to stabilize for 24 hours. Compare this temperature to the fluid thermometer and adjust the 
console to match the fluid thermometer. 
 
To calibrate indoor or outdoor temperature, in the Set Mode with indoor or outdoor temperature 
flashing, press the 

+

 key or 

MIN/MAX

 key to increase or decrease the temperature setting (in 

increments of 0.1 degC or 0.18 degF) to match the calibrated or known temperature source. 
 

Note: 

The remote (outdoor) thermo-hygrometer will always display the measured temperature 

level and not the calibrated temperature level. Only the console will show the calibrated value.   
 

Note: 

The dew point calculation is based on the calibrated temperature level. 

4.3

 

Alarm

 

Mode

 

4.3.1

 

Alarm

 

Display

 

While in Normal Mode, press the 

ALARM

 key to enter the High Alarm Mode.    Press the 

ALARM

 

key again to enter the Low Alarm Mode. Press the 

ALARM

 key again to return to normal mode (or 

wait 30 seconds for the programming mode to timeout). 
 

Note:  

After entering the

 ALARM 

mode,

 

the console will display the high and low alarm 

settings. If the value reads 

--.-- 

(dashes), the alarm is not active. 

4.3.2

 

Alarm

 

Programming

 

While in Alarm Mode, press the 

SET

 key to set the alarms. The following are high and low alarms: 

 

High Alarm Limits: 

 

Time alarm (hour/minute) 

 

Indoor humidity high alarm 

 

Indoor temperature high alarm 

 

Outdoor humidity high alarm 

 

Outdoor temperature / dew point high alarm   

 

Pressure high alarm 

 

Low Alarm Limits:     

 

In the Low Alarm Mode press the SET key to select the following alarm modes: 

 

Time alarm (hour/minute) 

 

Indoor humidity low alarm 

 

Indoor temperature low alarm 

 

Outdoor humidity low alarm 

 

Outdoor temperature / dew point low alarm 

 

Pressure low alarm 

 
 
 

Summary of Contents for WH117L

Page 1: ...eration 8 4 2 3 Setting Barometric Pressure 10 4 2 4 Setting Calibrated Humidity 11 4 2 5 Setting Calibrated Temperature 11 4 3 Alarm Mode 12 4 3 1 Alarm Display 12 4 3 2 Alarm Programming 12 4 3 3 Ca...

Page 2: ...r WH2F The following user guide provides step by step instructions for installation operation and troubleshooting Product Features Figure 1 No Description No Description 1 Radio Controlled Clock with...

Page 3: ...Display Console Frame Dimensions LxWxH 7 25 x 4 x 1 25 in LCD Dimensions LxW 4 25 x 2 50 1 Thermo hygrometer transmitter WH2F with mounting bracket Dimensions LxWxH 3 5 x 2 5 x 0 9 2 2 Recommend Tools...

Page 4: ...ree AA alkaline or lithium avoid rechargeable batteries in the back of the display console Looking at the back of the unit left to right the polarity is for the top battery for the middle battery and...

Page 5: ...oid interference If the signal reception is not successful normally during the day due to solar interference the sensor search will be cancelled the outdoor temperature and humidity will update as nor...

Page 6: ...ze key is on the top of the display console 2 4 3 Sensor Operation Verification Verify the indoor and outdoor humidity match closely with the console and sensor array in the same location about 10 apa...

Page 7: ...key and key There are four program modes Quick Display Mode Set Mode Alarm Mode and Min Max Mode Any program mode can be exited at any time by either pressing the SNOOZE LIGHT key on the top of the d...

Page 8: ...Pressure Calibration Press to increase MIN MAX to decrease SET Pressure Threshold for Forecast Press to increase MIN MAX to decrease SET Storm Threshold for Forecast Press to increase MIN MAX to decr...

Page 9: ...ndard Tokyo 10 GST Guam Standard Sydney 11 Magadan 12 IDLE International Date Line East NZST New Zealand Standard Wellington New Zealand 3 12 24 Hour Format Press the SET key again to adjust the 12 24...

Page 10: ...re details on this feature 13 Outdoor Humidity Calibration default is measured outdoor humidity Press the SET key to adjust the outdoor humidity Press the key or MIN MAX key to adjust the relative hum...

Page 11: ...ch the official reporting station 4 2 4 Setting Calibrated Humidity Note This is a continuation of the previous section To enter this mode you must start at the beginning of this section The display c...

Page 12: ...play the measured temperature level and not the calibrated temperature level Only the console will show the calibrated value Note The dew point calculation is based on the calibrated temperature level...

Page 13: ...h for 120 seconds Press any key to cancel the alarm When an alarm condition is activated again within 10 minutes the alarm will not sound but will continue to flash until the weather condition is stab...

Page 14: ...ess the SNOOZE key or wait 30 seconds for the programming mode to timeout and the Min Max mode will return to Normal Mode 4 5 Other Console Features The following section describes additional console...

Page 15: ...right indicates that the air pressure is increasing and the weather is expected to improve The arrow pointing the left indicates that the air pressure is decreasing and the weather is expected to det...

Page 16: ...24 hours Each bar represents three hours The vertical scale of the graph is auto scaled There is not fixed pressure level for each bar and is intended for visualizing trends only 4 5 8 Restoring Lost...

Page 17: ...smission in open air 300 feet Frequency 433 92 MHz Update Rate 48 seconds 6 2 Measurement Specifications The following table provides specifications for the measured parameters Measurement Range Accur...

Page 18: ...Move the remote sensor to a higher location Move the remote sensor to a closer location 9 Radio Frequency RF Sensors cannot transmit through metal barriers example aluminum siding or multiple thick w...

Page 19: ...Lithium Battery 2 pack Batteries for Long Life and Cold Climates AA lithium batteries for cold weather climates Ambient Weather SRS100LX Temperature and Humidity Solar Radiation Shield Solar Radiatio...

Page 20: ...void the user s authority to operate the equipment Statement according to FCC part 15 105 NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant...