50D0112
RCSTEBA Installation & Operating Manual
Rel 1.0 April 2009
Page 6 of 10
Ambient Technologies
A Division Of
Monessen Hearth Systems
WAR
N
ING
Do not use two (2) or more remote control systems in the same area with the same dip switch
settings, as they will communicate with each other. This may cause the appliances to
malfunction.
Reset Button:
1.
The reset button can be used to reset the transmitter if transmitter is not working properly. The reset
button (recessed) is located behind the battery door cover in the lower left corner of battery comparment.
Using a paper clip, press the reset button and the transmitter will reset and initialize for 10 seconds before it
can be used.
OPERATIONS
Transmitter:
General:
The RCSTEBA Remote Control has two (2) operating modes: Manual and
Thermostatic. The control system can be set to temperature ranges between 45°F and
90°F. The blower speed can be adjusted in either the manual and thermostatic mode.
The transmitter will operate the remote receiver from 1foot to a maximum of 30 feet.
The distance is reduced when batteries are low or when the receiver is inside a metal
enclosure.
Initial start up:
1. After initial power up or when RESET button is pressed, the transmitter is reset.
The reset button is located behind the battery door of transmitter.
2. During system reset, all features of the LCD will be visible. After one second,
the LCD will be initialized. A typical reset display is shown above. Note that
the temperature scale is degree F.
3. When only the "F" is displayed without the number, press On button to select
between °C and °F display. It will exit setting mode automatically after 10
seconds if no key is pressed. The transmitter will send an Off signal after reset.
4. After reset, the transmitter is operating in manual mode. The room temperature
is shown as above.