MAINTENANCE

UPKEEP & CARE

TECHNICAL SPECIFICATIONS

• 

Before any maintenance operation ensure that the power source is disconnected and that the switch is 
in the off position

• 

Before any maintenance wait for the unit to cool down completely

• 

Clean the outside surface with a soft cloth and liquid detergent or stainless steel cleaner 

• 

Do not use abrasive cleaning or scouring products

• 

To maintain the delicate external finishes use the following methods with each finish:

High-quality and high technology, given by a product certified and ratified according to European and American norms for 
electrical devices, made of components that meet the standard requirement of current safety regulations: The product’s Heat 
Controller is certified ETL Canada and CE with protection degree IP54 that ensures consumer safety.

Surface temperatures of appliances during normal operations are maintained below the temperature of 60–65°c / 140–149°f 
without towels, and 90°c / 194°f with towels, as required by following standards:

• 

For residue buildup do not use extreme pressure on the surface to avoid scratches & damages to the heater

• 

It is also possible to use a solvent — use caution & make sure to read the technical forms and norms for it’s use

• 

In case of uncertainty, do not hesitate to contact Amba Products

Amba Products declines any responsibility if these instructions are not followed

• 

Brushed finishes: rub the soft cloth following the grain of the finish

• 

Polished finishes: do not rub cloth in a circular motion – do not use excessive force

• 

Oil-Rubbed Bronze finishes: rub with non-abrasive cloth using warm, soapy water

115v–10A  60Hz  

UL 2021

  SAFETY FIXED AND LOCATION-DEDICATED ELECTRIC ROOM HEATERS

220v--5A  50Hz 

CE EUROPEAN NORM

CSA C22.2 No. 46

  ELECTRICAL AIR-HEATERS, ENVIRONMENTAL PRODUCTS GENERAL INSTRUCTION No. 1

Normal Temperature of Appliance
Temperature of Appliance with Towel

MODEL

QUADRO

60–65°C
85–90°C

140–149°F
185–194°F

Summary of Contents for Quadro Q2052

Page 1: ... SKU Width HEIGHT Power Amps BTU Q2016 20 1 2 16 3 4 92 watts 0 8 314 Q2033 20 1 2 33 1 4 172 watts 1 5 586 Q2042 20 1 2 42 5 16 232 watts 2 0 791 Q2052 20 1 2 54 1 2 296 watts 2 6 1009 Q2833 28 3 8 33 1 4 232 watts 2 0 791 Q2842 28 3 8 42 3 8 296 watts 2 6 1009 COMPONENTS 1 2 3 4 5 6 8 7 1 Plastic Anchor 2 Threaded Wall Support 3 Anchor Screw 4 Threaded Long Tube 5 Cover 6 Setscrew 7 Fixing Screw...

Page 2: ...ired The unit has to be connected to a power supply circuit equipped with an omni polar disconnection electrical system with a distance among contacts of 1 8 Caution high temperature risk of fire keep electrical cords drapery furnishings other combustibles away from the front of the heater Bad smells may be caused by residues inside the heater or by the inner plastic parts as unit operates with no...

Page 3: ...during normal operations are maintained below the temperature of 60 65 c 140 149 f without towels and 90 c 194 f with towels as required by following standards For residue buildup do not use extreme pressure on the surface to avoid scratches damages to the heater It is also possible to use a solvent use caution make sure to read the technical forms and norms for it s use In case of uncertainty do ...

Page 4: ...uctural members behind the drywall If not possible on both sides toggle bolts can be used on one side Proceed laying the threaded wall support point 2 on the hole and fasten it with the anchor bolt screw repeat this procedure also for the other points marked on the wall Fixing Screw Bushing BACK SIDE OF TOWEL WARMER Laythe bushing point 6 on the holes of the towel warmer And fasten it with the fix...

Page 5: ...or use only Ensure that room trip switch is off before any operation Wrong wiring connection to the power source will cause sparks and the burning damage to the digital heat controller carefully consult the wiring diagram Do not insert foreign bodies inside the digital heat controller in order to avoid electric shocks or damages to it Do not use the digital heat controller close to combustibles pa...

Page 6: ...HC Output cable D Towel Warmer cable E Ground faston POWER REGULATOR 1 Connect T1 A T2 B T3 D to faston T E 2 Connect L 1 A L2 B 3 Connect N 1 A N2 8 4 Connect N3 0 N4 C 5 Connect L3 0 L4 C Level Settings 1 Minimum Heat 9 Maximum Heat Can be wired in conjunction with a programmable timer CONSULT ELECTRICIAN STEP 1 STEP 2 ...

Page 7: ...t the fastenings of the towel warmer s cable to the other section See the example below Connect one cable to the left section Electrical bridge 1 1 2 2 Connect the other cable to the right Electrical bridge 1 2 2 1 Fix the stainless steel wall plate with the provided screws Power source cable Fastening Connections Step 2 Towel warmer cable COMPONENTS WALL PLATE FASTENING CONNECTIONS SWITCH INSTALL...