General instructions:
1. [ENTER] moves between fields and accepts changes
2. [BACK] goes to a previous field and saves the setting only when you are on the name
of the relay (P1LS, P1LE, etc.)
3. [UP] and [DOWN] change values
Changing settings:
1. Press [ENTER] to edit the closure map and highlight P1LS
2. Press [ENTER] to move to the relay – this will be 1 in the default settings
3. Press [UP] or [DOWN] to change this to any of the available relays (in the default
setting, only relays #1-#4 are available)
4. Press [ENTER] to move to the state – in the default settings, this will be ON
5. Press [UP] or [DOWN] to change the setting from ON to OFF or PULSE
6. Press [ENTER] to highlight P1LS
7. Press [BACK] to save your setting
Until you press [BACK] you will rotate through the NAME, RELAY and STATE.
To reset the closure map to its default settings, you must enter the Relay Test Menu
(pressing [UP] and [DOWN] at the same time) and then press [UP] and [DOWN] at the
same time while in the Relay Test Menu. The following section describes that procedure.
Resetting to Default Closures
menu, you can press [UP] and [DOWN] at the same time to
reset the closure map to its default setting.
Relay Test Menu
This menu allows you to verify input closures and close the relays to verify connections. The
menu item is not listed and is activated by pressing [UP] and [DOWN] at the same time
while you are in the Closure Map submenu.
Closure Test
1. Press [ENTER] to enter the closure test
2. Press [UP] or [DOWN] to select the relay you want to test
Relay #1 selected, but not activated
3. Press [ENTER] to activate a relay – the box of the selected relay will darken
Relay #1 Activated
4. Press [ENTER] to clear the relay – the box of the selected relay will lighten
5. Press [BACK] to exit the closure test and return to the Settings submenu
When an input closure is closed, the appropriate box goes black and then clears after it is
released.
Input #1 closed, inputs #2, #3 and #4 open
Rev. 1 – Firmware version 2.03
31
©
2012