background image

 

 

 

 

Cleaning, maintenance and repairs 

 

AMADOS  BAG0083.2  11.17

 

 

31

 

 

Cleaning, maintenance and repairs 

 

8.1 

Cleaning 

 

CAUTION 

Take great care when cleaning the 

E+S

 with a high-pressure 

cleaner. 

Never clean the setting motor with a high-pressure cleaner, as 
this could damage the setting motor! 

8.2 

Storage 

 

Store the board computer in a dry environment when removing it from 
the tractor cab. 

8.3 

Service menu 

 

To limit a possible malfunction, the input of data can be indicated on 
the display. 

  1.  Actuate the 

and 

 keys simultaneously. 

 

Input E1 is displayed. 

  2.  Actuate the 

 or 

 keys. 

 

To display the inputs E1 to E3 

  3.  Actuate the 

 key. 

 

Back to work display 

 

 

Display, input 1 

 

E1 

Wheel impulses 

The impulses from the distance sensor or the signal socket of the 
tractor are counted. 

E2 

Analogue value of rate 
slider 

Actuate the 

 or 

 key.  

 

Setting motor moves, voltage at sensor is displayed  
(0.5V -4.5 V). 

 

E3 

Analogue value of bor-
der spread deflector 

Actuate the 

 or 

 key.  

 

Setting motor moves, voltage at sensor is displayed  
(0.5V -4.5 V). 

Summary of Contents for AMADOS E+S

Page 1: ...Operating Manual az AMADOS E S On board computer MG3523 BAG0083 2 11 17 Printed in Germany Please read this operating manual before first commissioning Keep it in a safe place for future use en ...

Page 2: ...itself The person in question would not only harm himself but also make the mistake of blaming the machine for pos sible failures instead of himself In order to ensure success one should enter the mind of a thing make himself familiar with every part of the ma chine and get acquainted with how it s handled Only in this way could you be satisfied both with the machine and with yourself This goal is...

Page 3: ...1 5 3 Determine impulses per 100m 14 5 4 Enter working width 16 5 5 Entering the spread rate and starting a job 17 5 5 1 Display of job data 19 5 5 2 Deleting job data 20 5 5 3 External job ASD 20 5 6 Carrying out spread rate check 21 6 Use 24 6 1 Predosing 25 6 2 Setting the working width via the border spread deflector 26 6 3 Blockage 26 6 4 Changing the spread rate during spreading 27 6 5 Displ...

Page 4: ... in the operating manual are always seen from the direction of travel 1 3 Diagrams used Handling instructions and reactions Activities to be carried out by the user are given as numbered instruc tions Always keep to the order of the handling instructions The reac tion to the handling instructions is given by an arrow Example 1 Handling instruction 1 Reaction of the machine to handling instruction ...

Page 5: ...l result in death or serious physical injury loss of body parts or long term damage if not avoided If the instructions are not followed then this will result in imme diate death or serious physical injury WARNING Indicates a medium risk which could result in death or serious physical injury if not avoided If the instructions are not followed then this may result in death or serious physical injury...

Page 6: ...ludes Compliance with all the instructions in this operating manual Execution of inspection and maintenance work Exclusive use of original AMAZONE spare parts Other uses to those specified above are forbidden and shall be con sidered as improper For any damage resulting from improper use the operator bears the sole responsibility AMAZONEN WERKE assumes no liability whatsoever 3 2 Technical data Su...

Page 7: ...n compliance with the area specific spread rate quantity adjustment Job administration 4 2 Display Information on the display 1 The current forward speed in km h during use 2 The current spread rate in g m 2 during use 3 Display Fault message 4 Shutter open 5 Display Percentage deviation from the specified spread rate 6 Display ο Permanently illuminated Spread area in job m 2 ο Flashing Total spre...

Page 8: ...isplay Select job Start finish automatic quantity regulation Open close shutter Increase working width Reduce working width Start predosing Eliminate blockage by completely opening the shutter Blue keys Work data Display of the worked area m 2 for the cur rent job Second press of key Display of the spread distance for the current job Third press of key Display of the spread quantity kg for the cur...

Page 9: ...determine impulses per 100 m Display spread rate as scale value Select mode Enter determine calibration factor Key combinations Display of the total worked area Start calibration run for impulses per 100 m Allow change of modes Calibrate product Service menu Adjust offset value in case of varying working widths ...

Page 10: ...e spreader for the first time the opera tor must have read and understood the operating manual See also the operating manual for the fertiliser spreader 5 1 Connect AMADOS E S 1 Connect the machine mounted attached to the tractor via the machine connector Fig 1 1 2 Connect the signal cable from the tractor signal socket or the sensor X Fig 1 2 to the AMADOS E S Fig 1 ...

Page 11: ...ral times Display of other modes 1 9 Display of mode 2 After initial actuation of the key mode 2 always appears product Mode 2 can also be changed without deblocking Changing modes 1 9 1 Actuate the and keys simultaneously Deblock the stored modes 2 Actuate the key and select the mode to be changed 3 Enter the value with the or keys 4 Confirm with the key 5 With the key select another mode for cha...

Page 12: ...5 km h The higher the starting speed the greater the spread rate when start ing Mode 5 Duration of predosing until automatic quantity regulation starts in seconds Factory setting maximum value 5 seconds Mode 6 Enter maximum number of jobs to be started Factory setting 20 maximum value 99 Mode 7 Enter planned mean working speed AMADOS requires the entry to determine the fertiliser calibration facto...

Page 13: ...Commissioning AMADOS BAG0083 2 11 17 13 57 600 baud factory setting 19 200 baud ...

Page 14: ... or after changing to different sized tractor tyres if there is a discrepancy between the measured and the actual travel speed distance travelled if there is a discrepancy between the measured and the actual worked area with different ground conditions The Impulses per 100 m calibration value must be established under the prevailing conditions If the tractor is to be used with all wheel drive swit...

Page 15: ...rk menu ο automatically after 10 seconds ο with the key Enter the impulses per 100m 1 With the vehicle at standstill press 2 Enter the value with the or keys 3 Accept with the key 4 Confirm with the key 5 Back to work menu ο automatically after 10 seconds ο with the key The required minimum value for the impulses per 100 m is 200 ...

Page 16: ...ding to the table below Adjustable working widths m Salt 1 5 4 Sand gravel slag 2 5 Fertiliser 1 10 Allocation of panel position to working width Product 1 2 3 4 5 Spread deflector position Gravel Sand Salt Slag Fertiliser 90 5 5 4 5 X 60 4 4 3 4 45 3 3 2 3 30 2 2 1 5 2 Working width m The smallest adjustable position of the spread deflector is 30 The spread deflector is raised completely 90 for s...

Page 17: ...tered for the started job is spread ο the field plot for the started job the total area is deter mined Display of spread rate 1 Actuate the key with the vehicle at standstill The last processed job appears on the display 2 Select a job with the key 3 Use the or key to enter the desired spread rate g m 2 e g 50 for a spread rate of 50 g m 2 4 Confirm with the key Adjustable spread rates g m 2 Salt ...

Page 18: ...bs can be created as standard If this is insufficient the number of jobs to be created can be in creased to 99 To do so 1 Actuate the and keys simultaneously 2 Select mode 6 3 Use the keys to enter the number of jobs to be created 4 Confirm with the key ...

Page 19: ...uate the key The worked area in m 2 is displayed for the job Display of area 2 Actuate the key again The distance travelled in km is displayed for the job Display of distance 3 Actuate the key again The spread rate in kg is displayed for the job Display of quantity indicating kg 4 Actuate the key work display By actuating the key combination and the total area in ha for all jobs can be displayed ...

Page 20: ...ed to the AMADOS E S This job is always given the designation AE Fig 2 Fig 2 The data is transferred via the serial interface For this purpose set the transfer rate of the serial interface to 19200 or 57600 baud mode 9 The Y cable is required for this Fig 3 1 Connection for PDA computer 2 Connection for signal socket or sensor for impulses per minute 3 Connection to AMADOS E S 4 The external job i...

Page 21: ...ing of the tractor s three point hydraulic system The calibration factor for the product determines the regulating be haviour of the AMADOS E S and depends on the flow characteristics of the product to be spread the entered spread rate the entered working width The product flow characteristics may change even after a brief storage period Therefore again determine the calibration factor for the pro...

Page 22: ...rate job Desired working width Product mode 2 Intended average speed mode 7 2 Add a sufficient quantity of product to the hopper 3 Press the key 4 Enter a calibration value on the display via the or keys e g 1 00 standard value Values based on experience can be used to enter the calibration factor Display after entry of calibration factor 5 Press the key and confirm 6 Press the key hold and at sam...

Page 23: ... The scales used must weigh ac curately Significant inaccuracies may cause deviations in the ac tual spread rate Take the bucket weight into con sideration 11 Select the weight of the product via the or keys on the display e g 1 50 for 1 5 kg 12 Press the key and confirm AMADOS E S determines the calibration factor 13 Press the key and the calibration factor is displayed By actuating the key the c...

Page 24: ...ent job can be dis played Procedure for use 1 Switch on the AMADOS E S 2 Select the job Check the specified quantity or Enter the specified quantity and confirm 3 Back to work menu 4 Move off and start the automatic quantity regulation ο Start the automatic quantity regulation or ο start the automatic quantity regulation with predos ing for the first metres Check whether the actual working width c...

Page 25: ...ntity regulation switched on 4 Reception of impulses for determining distance travelled 5 Shutter open Work display 6 1 Predosing Switch on the automatic quantity regulation via the key Over the first metres a higher dosing is set in order to ensure a sufficient spread rate for a quick start Beforehand ο Theoretical starting speed mode 4 ο Set duration of predosing mode 5 After the predosing the q...

Page 26: ... deflector angle The stored working width is modified by changing the spread deflector angle The adjustment of the spread rate area specific spread rate takes place automatically When spreading fertilizer adjusting the working width via the spread deflector is not possible Adjustable working widths see page 16 6 3 Blockage Blockages in the dosing unit can be eliminated by pressing the key Only pos...

Page 27: ...ars If the key is pressed several times the spread rate is changed by a multiple amount The spread rate change in is displayed for five seconds then the work display reappears The triangle symbol in the work display indicates a spread rate change 6 5 Display of the bottom group shutter position During the spreading process the current shutter setting can be dis played 1 Press the key with the quan...

Page 28: ... draining cleaning Open the shutter to drain the residue and clean the hopper 1 Actuate the key with the machine at standstill 2 Actuate the key The shutter opens fully 3 Actuate the key Shutter closes Display of current shutter position 0 55 ...

Page 29: ... cali bration Start job and enter specified value A12 No working width start of calibra tion Enter working width A13 The value from the spread width sensor is incorrect Check cable Motor or sensor defective A14 The value from the spread rate sensor is incorrect Check cable Motor or sensor defective A15 No calibration factor Enter determine calibration factor Display of alarm message ...

Page 30: ...e 1 To select offset Press the and keys simulta neously Display working width spread deflector angle Working width m spread deflector angle 2 Raise or lower the spread deflector using the or keys until the true working width is reached Only the value of the diffusing panel angle is modified on the display The value of the working width remains constant 3 Store with the key The offset value remains...

Page 31: ...To limit a possible malfunction the input of data can be indicated on the display 1 Actuate the and keys simultaneously Input E1 is displayed 2 Actuate the or keys To display the inputs E1 to E3 3 Actuate the key Back to work display Display input 1 E1 Wheel impulses The impulses from the distance sensor or the signal socket of the tractor are counted E2 Analogue value of rate slider Actuate the o...

Page 32: ......

Reviews: