Commissioning
12
AMADOS BAG0083.2 11.17
Mode 1
Select machine type.
1 = E+S 300, E+S 750 (Setting after a reset)
2 = E+S 301, E+S 751 (factory setting)
Mode 2
Select product.
1 = Grit
2 = Sand (not for E+S 01)
3 = Salt (factory setting)
4 = Gravel (not for E+S 01)
5 = Fertiliser (not for E+S 01)
Mode 3
Enter application rate increase in %.
Entry of reduction or increase of spread rate per key press
.
(Factory setting 10%)
Mode 4
Theoretical starting speed for predosing in km/h.
(Factory setting / maximum value 15 km/h)
The higher the starting speed, the greater the spread rate when start-
ing.
Mode 5
Duration of predosing until automatic quantity regulation starts
in seconds.
(Factory setting / maximum value 5 seconds)
Mode 6
Enter maximum number of jobs to be started.
(Factory setting 20, maximum value 99)
Mode 7
Enter planned mean working speed.
AMADOS
+
requires the entry to determine the fertiliser calibration
factor.
(Factory setting 12 km)
Mode 8
Enter theoretical travel speed for travel simulator.
With defective speed sensor
(Factory setting 0 km/h
→
Travel simulator off
→
The speed is deter-
mined from the impulses from the wheel.)
Mode 9
Enter transfer rate of serial interface.
For external job.