background image

9

EN

•  Remove the cover on the base of the head (D).

•  Remove the cover on the top of the arm (K).

•  Connect the two pieces together.

•  Fasten the head (D) using the screw on the arm (K).

20

18

0

160

140

120

0

10

170

160

150

140

130

120

110

100

180

190

0

10

20

30

40

50

10

0

60

70

65

75

E

X

W

Y

V

•  Attach the objective lenses (V, W, X, Y) in a clockwise sequence 

according to increasing magnification power onto the nose piece (E).

Light source option

20

18

0

160

140

120

0

10

170

160

150

140

130

120

110

100

180

190

0

10

20

30

40

50

10

0

60

70

65

75

AD

AE

I

Summary of Contents for B07TWLF9Z2

Page 1: ...cular Microscope Microscopio Binocular Compuesto Microscope Composé Binoculaire B07TWLF9Z2 18 0 1 4 0 120 100 80 160 0 1 7 0 1 6 0 1 5 0 1 4 0 1 3 0 1 2 0 1 1 0 1 0 0 1 8 0 1 9 0 0 10 20 30 40 50 10 0 60 7 0 6 5 7 5 ...

Page 2: ...English 5 Español 16 Français 26 ...

Page 3: ...3 18 0 1 4 0 120 100 80 160 0 1 7 0 1 6 0 1 5 0 1 4 0 1 3 0 1 2 0 11 0 1 0 0 1 8 0 1 9 0 0 10 20 30 40 50 10 0 60 7 0 6 5 7 5 J H I G F C D E A B K L M P N Q R S U O T AH AG ...

Page 4: ...4 V Z W X Y AA AB AC AD AE AF ...

Page 5: ...tive lens G Stage X 40x objective lens H Condenser Y 100x objective lens I Transmitted light lamp Z 10x eyepiece x2 J Base AA 20x eyepiece x2 K Arm AB Color filter green L Coarse adjustment knob AC Dust cover M Fine adjustment knob AD Mirror N X axis translation control AE Mirror stand O Y axis translation control AF Detachable power cord with plug P Power socket AG Condenser locking screw Q Brigh...

Page 6: ...ical attention if irritation develops First aid in case of skin contact Immediately flush skin with excess water for 15 minutes while removing contaminated clothing Get medical attention if irritation develops First aid in case of ingestion Do not induce vomiting without medical advice Consult a physician if necessary NOTICE Methylene Blue dye has been classified by the International Agency for Re...

Page 7: ...l it is properly repaired Store the set in its original packaging out of reach of children and animals Grounding Instructions This product must be grounded while in use to protect the operator from electrical shock The appliance is equipped with a 3 conductor cord and a 3 prong grounding type plug to fit the proper grounding type receptacle The appliance has a plug that looks like sketch A in the ...

Page 8: ...This product is intended to be used in dry indoor areas only No liability will be accepted for damages resulting from improper use or non compliance with these instructions Before First Use Check the product for transport damages DANGER Risk of suffocation Keep any packaging materials away from children these materials are a potential source of danger e g suffocation Assembly 120 100 80 1 7 0 1 6 ...

Page 9: ... 120 0 1 0 1 7 0 1 6 0 1 5 0 1 4 0 1 3 0 1 2 0 1 1 0 1 0 0 1 8 0 1 9 0 0 1 0 2 0 3 0 4 0 5 0 10 0 6 0 7 0 6 5 7 5 E X W Y V Attach the objective lenses V W X Y in a clockwise sequence according to increasing magnification power onto the nose piece E Light source option 20 1 8 0 160 140 120 0 10 17 0 16 0 15 0 14 0 13 0 12 0 11 0 10 0 18 0 19 0 0 10 20 30 40 50 10 0 60 70 65 75 AD AE I ...

Page 10: ...et P NOTICE To prevent the bulb in the lamp I from burning turn the brightness adjustment wheel Q setting to the lowest before turning on or off Flip the power switch R to I to turn on the lamp I After use flip the power switch R to O to turn off Calculating magnification power Total magnification power is calculated by multiplying the magnification power of the eyepiece and the objective lens Eye...

Page 11: ...te the nose piece E to the lowest magnification power setting NOTICE Start with the lowest magnification power every time a new slide is placed on the stage G Most observations are made at low magnification power Clip a slide not included onto the stage G securing with the stage clip F Without looking into the eyepiece Z AA turn the coarse focus knob L until the objective lens is close to the slid...

Page 12: ...n further once the knob is already restrained from turning It may cause friction and scratch the lenses The condenser H is adjusted to focus the light unto the specimen Tinker around with the condenser H s vertical knob U diaphragm T and the locking screw AG to achieve the sharpest image NOTICE The condenser diaphragm T gathers the available light and concentrates it to illuminate over the specime...

Page 13: ...vent electric shock unplug the product before cleaning CAUTION Risk of electric shock During cleaning do not immerse the product in water or other liquids Never hold the product under running water Cleaning To clean the lenses V W X Y Z AA only use lens cleaning tissues Do not use cloth paper or hands Rotate the objective lenses V W X Y counter clockwise to remove them from the nose piece E To cle...

Page 14: ... of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a partic...

Page 15: ...be 1 2 Diameter of filter Ø 1 25 32 mm Working temperature 50 to 104 F 10 to 40 C R H range 30 to 75 Net weight approx 24 2 lbs 11 kg Dimensions W x H x D approx 9 53 x 14 76 x 7 09 24 x 37 5 x 18 cm Feedback and Help Love it Hate it Let us know with a customer review AmazonBasics is committed to delivering customer driven products that live up to your high standards We encourage you to write a re...

Page 16: ...amazon com AmazonBasics V01 08 19 MADE IN CHINA HECHO EN CHINA FABRIQUÉ EN CHINE ...

Reviews: