WKM900 

 

A Wiegand Keypad Mullion Reader (WKM900-1-AC-XX) housed in a Black, ABS 
Plastic housing.  The Wiegand Reader consists of a Front Cover and a Mounting 
Bracket (the Mounting Bracket is attached with a Self-tapping Screw (M2 x 6 mm)). 

 

A 1 m Wiegand Connector Cable. 

 

One 2-Way Programming Pin. 

 

Two Counter-sunk Self-tapping Screws (M2 x 6 mm). 

 

Two Counter-sunk Self-taping Screws (2. Mm x 25 mm). 

 

Two Wall Plugs (5 mm). 

 

An extra Serial Number Label. 

General 

Remember the following when installing the Wiegand Readers: 

Maximum Data Communications Distance 

CAUTION: 

When implementing the 150 m cable distances with the Wiegand 
Readers use the 12 V power input option. 

Install the Wiegand Readers no further than 150 m (164 yd) from the Host unit.  The 
cable individual conductor cross-sectional area should not be less than 0.2 mm

2

 

(0.0003 in

2

).   

Distance between Wiegand Readers 

To avoid mutual interference, install the Wiegand Readers no closer than 500 mm (20 
in) apart. 

Mounting the Wiegand Readers 

CAUTION: 

Make certain that you mount the Readers on a vibration-free 
surface. 

Select the mounting position of the Wiegand Readers, considering accessibility, routing 
of wires and visibility of the externally visible LED. 

Secure the Wiegand Readers to the mounting surface, using four suitable screws and 
wall plugs (supplied), nuts and bolts or rivets.   

NOTE: 

The Wiegand Door Entry Panel is designed for mounting in a user supplied 
enclosure.  The Reader has 4 mounting holes, drilled to 4 mm in diameter.  
The mounting holes accommodate M3 bolts and nuts. 

 

 
 
 

Blank Space 

 

 

 

 

Summary of Contents for WDP900-1-0-AC Series

Page 1: ...outdoor environments similar to IP53 NOTE These Readers are RoHS compliant and do not contain any UV stabilizer WMR900 and WMK900 Designed to work in harsh industrial indoor or outdoor environments si...

Page 2: ...ation 26 bit Wiegand only Inputs Quantity 4 Type Dry Contact Function Operation of the Buzzer LED and Scanner Inhibit Buzzer 4 kHz piezo electric single volume single tone Status Indicators Status LED...

Page 3: ...gs 7 mm An extra Serial Number Label WMR900 and WMK900 Either a Wiegand Metal Non Keypad Reader WMR900 1 0 AC XX housed in a Zinc alloy die cast housing The Wiegand Reader consists of a Front Cover an...

Page 4: ...Install the Wiegand Readers no further than 150 m 164 yd from the Host unit The cable individual conductor cross sectional area should not be less than 0 2 mm 2 0 0003 in 2 Distance between Wiegand Re...

Page 5: ...0 AC 04 March 2009 Page 5 ELECTRICAL CONNECTIONS Connecting the Wiegand Reader Figure 1 to Figure 5 show typical connection diagrams for the Wiegand Reader Figure 1 Wiegand Reader Connected to the Am...

Page 6: ...WPR300 0 0 AC 04 March 2009 Page 6 Figure 2 Wiegand Reader Connected to the Nexus 220 Controller...

Page 7: ...WPR300 0 0 AC 04 March 2009 Page 7 Figure 3 Wiegand Reader Connected to the Amano MfT or the AXP121 Controller...

Page 8: ...WPR300 0 0 AC 04 March 2009 Page 8 Figure 4 Wiegand Reader Connected to the Amano TA or Amano iTA...

Page 9: ...WPR300 0 0 AC 04 March 2009 Page 9 Figure 5 Wiegand Reader Connected to the Amano RL Amano RS and Amano RH...

Page 10: ...rmal or 45 bit raw mode Figure 6 Wiegand Pin Placement Setting the Wiegand Mode The Output Mode can be selected by doing the following 1 Remove the Backing Plate from the Wiegand Reader 2 Short circui...

Page 11: ...ed from the information in the tag and will vary between tags The 26 bit or 44 bit selection does not impact on HID Tags HID Raw In this Mode the entire raw 45 bit HID Tag is output Keypad Model Setti...

Page 12: ...ty option in the Fixed Length Mode is set as follows 1 Press and hold down key 2 for 3 seconds The Status LED enters a fast flash Mode and emits a long beep 2 Enter a 3 digit number followed by the Ha...

Page 13: ...h Key 3 On acceptance of the change the Status LED will change to Green 4 If the change is rejected the Status LED will change to Red Entering a Facility Code A Facility Code only applies when PIN cod...

Page 14: ...hen connected to a Terminal or Controller the Wiegand Reader is assigned one of the available Fixed Addresses The Serial Number Label identifies the type of Wiegand Reader and the Fixed Address Label...

Page 15: ...WPR300 0 0 AC 04 March 2009 Page 15 USER NOTES...

Page 16: ...nd NJ 07068 1239 800 526 2559 www amano com This manual is applicable to the Wiegand Readers WPR900 1 0 AC 00 WPK900 1 0 AC 00 WMR900 1 0 AC 00 WMK900 1 0 AC 00 WDP900 1 0 AC 00 and WKM900 1 0 AC 00 T...

Reviews: